Troubleshooting guide – Maytag HRN4975S User Manual

Page 27

Advertising
background image

27

TROUBLESHOOTING GUIDE

TROUBLESHOOTING GUIDE

TROUBLESHOOTING GUIDE

TROUBLESHOOTING GUIDE

TROUBLESHOOTING GUIDE

These guidelines should be used by a qualified Maytag Customer Service Center Agent. Call the Maytag

Customer Service Center at 1-800-788-8899 for assistance.

Problem

Cause

Solution

Improperly sealed, hot or cold supply connection,

Tighten threaded connections.

relief valve, drain valve, or thermostat threads.
Leakage from other appliances or water lines.

Inspect other appliances near water heater.

Condensation of flue products.

Refer to CONDENSATION.

Thermal expansion in closed water system.

Install thermal expansion tank (DO NOT plug T&P valve).

Improperly seated valve.

Check relief valve for proper operation
(DO NOT plug T&P valve).

High sulfate or mineral content in water supply.

Drain and flush heater thoroughly, then refill.

Bacteria in water supply.

Chlorinate or aerate water supply.

Gas control knob not positioned correctly.

Refer to LIGHTING INSTRUCTIONS.

Main gas supply off.

Turn on main gas shut-off valve.

PILOT WILL NOT LIGHT

Thermocouple malfunction.

Replace pilot assembly and/or thermocouple.

Match not close to pilot.

Locate pilot, move match closer.

Thermocouple malfunction.

Replace pilot assembly
and/or thermocouple.

Defective Gas Control.

Replace Gas Control.

Dirty pilot burner.

Clean pilot assembly.

Thermocouple tip is not in contact with pilot flame.

Insert thermocouple correctly.

PILOT OUTAGE

Thermocouple malfunction.

Replace pilot assembly and/or thermocouple.

Defective Gas Control.

Replace Gas Control.

Heater not lit or thermostat not on.

Refer to LIGHTING INSTRUCTIONS.

Thermostat set too low.

Refer to TEMPERATURE REGULATION.

Heater undersized.

Reduce hot water use.

NOT ENOUGH

Low gas pressure.

Contact your gas supplier.

HOT WATER

Incoming water is unusually cold.

Allow more time for heater to re-heat.

Leaking hot water pipes or fixtures.

Have plumber check and repair leaks.

High temperature limit switch activated.

Contact a Maytag Customer Service Agent to
determine cause.

WATER TOO HOT

Thermostat set too high.

Refer to TEMPERATURE REGULATION.

WATER HEATER SOUNDS

Condensation dripping on burner.

Refer to CONDENSATION.

Sediment or calcium in bottom of heater tank.

Clean sediment from tank. Refer to DRAINING
instructions in Maintenance section of manual.

Improper combustion.

No adjustment available. Contact a Maytag Customer
Service Agent

to determine cause.

Lack of supply air.
Improperly installed vent piping.

Contact a Maytag Customer Service Agent to determine

Downdraft.

cause.

Poor combustion.

SOOTING

WATER LEAKS

LEAKING T&P VALVE

SMELLY WATER

VENT GAS ODORS

SIZZLING - RUMBLING

BURNER WILL NOT

STAY LIT

Advertising