Operating “Inside the Delta”

Using the RVS-DX soft starter “inside the delta” reduces the required soft starter rating by 1.73 (

√3)

factor. For example, for a 150 amp, 460 volt motor, the RVS-DX-170-D is selected to operate in
standard “line” mode. However, for “inside the delta” mode (150 amp

÷1.73=87 amps), the RVS-

DX-105-D can be selected, thereby, reducing cost and physical space in the application.

The following programming parameters are disabled, once the ‘inside the delta’ is selected:

•

Pulse Start

•

Pump Curve selection (only standard curve available)

•

Slow Speed and Slow Speed Reverse

•

Phase Sequence

The motor rating for standard “Line” and “Inside the Delta” connections are show here:

HP Ratings are approximate. The RVS-DX should always be sized by the motor full load amps for
“line” starting and the motor FLA/1.73=soft starter FLA for “inside delta”.

Model Number

RVS-DX FLA

HP at 460V for

“Line”

HP at 460V for

“Inside Delta”

RVS-DX-8-D

8

5

7.5

RVS-DX-17-D

17

10

15

RVS-DX-31-D

31

20

32

RVS-DX-44-D

44

30

50

RVS-DX-58-D

58

40

68

RVS-DX-72-D

72

50

85

RVS-DX-85-D

85

60

100

RVS-DX-105-D

105

75

125

RVS-DX-145-D

145

100

170

RVS-DX-170-D

170

125

215

RVS-DX-210-D

210

150

250

RVS-DX-310-D

310

200

340

RVS-DX-390-D

390

300

515