Customer responsibilities product specifications – Maytag HRN31240X User Manual

Page 5

Advertising
background image

5

TANK

RECOVERY

MINIMUM

DIMENSIONS

CAPACITY

TYPE

RATE GALS.

VENT PIPE

DIAMETER

IN INCHES (mm)

IN GALS

OF

BTU

PER HOUR

INCHES

INCHES

HEIGHT TOP OF

MODEL NUMBER

(LTRS)

GAS

RATE

@ 90°F RISE

(mm)

(mm)

DRAFT HOOD

HRN11240X

40 (151)

NATURAL

40,000

41.0

3" (76) or 4" (102)

20" (508)

63 1/2" (1,613)

*HRN31240X

40 (151)

NATURAL

40,000

41.0

3" (76) or 4" (102)

20" (508)

63 1/2" (1,613)

HRP11240X

40 (151)

PROPANE

35,500

36.0

3" (76) or 4" (102)

20" (508)

63 1/2" (1,613)

*HRP31240X

40 (151)

PROPANE

35,500

36.0

3" (76) or 4" (102)

20" (508)

63 1/2" (1,613)

HRN11250Q

50 (189)

NATURAL

65,000

67.4

4” (102)

22” (559)

65" (1,651)

HRN31250Q

50 (189)

NATURAL

65,000

67.4

4” (102)

22” (559)

65" (1,651)

HRP11250Q

50 (189)

PROPANE

55,000

57.0

4” (102)

22” (559)

65" (1,651)

HRP31250Q

50 (189)

PROPANE

55,000

57.0

4” (102)

22” (559)

65" (1,651)

HRN11250X

50 (189)

NATURAL

40,000

41.0

3" (76) or 4" (102)

22" (559)

65" (1,651)

*HRN31250X

50 (189)

NATURAL

40,000

41.0

3" (76) or 4" (102)

22" (559)

65" (1,651)

HRP11250X

50 (189)

PROPANE

35,500

36.0

3" (76) or 4" (102)

22" (559)

65" (1,651)

*HRP31250X

50 (189)

PROPANE

35,500

36.0

3" (76) or 4" (102)

22" (559)

65" (1,651)

Thank You for purchasing a Maytag water heater. Properly
installed and maintained, it should give you years of trouble
free service. It is strongly suggested that this new water heater
be professionally installed, contact Maytag Customer Service
(1-800-788-8899) for recommended installers
.

Abbreviations Found In This Instruction Manual:

CSA - Canadian Standards Association

ANSI - American National Standards Institute

NFPA - National Fire Protection Association

ASME - American Society of Mechanical Engineers

GAMA - Gas Appliance Manufacturers Association

This gas-fired water heater is design certified by CSA
INTERNATIONAL under American National Standard/CSA
Standard for Gas Water Heaters ANSI Z21.10.1 • CSA 4.1 (current
edition).

• Read the “Safety Precautions” section, page 3 of this manual

first and then the entire manual carefully. If you don’t follow
the safety rules, the water heater will not operate properly. It
could cause DEATH, SERIOUS BODILY INJURY AND/OR
PROPERTY DAMAGE.

This manual contains instructions for the installation,
operation, and maintenance of the gas-fired water heater. It
also contains warnings through out the manual that you must
read and be aware of. All warnings and all instructions are
essential to the proper operation of the water heater and
your safety. Since we cannot put everything on the first few
pages, READ THE ENTIRE MANUAL BEFORE ATTEMPTING
TO INSTALL OR OPERATE THE WATER HEATER.

The installation must conform with these instructions and
the local code authority having jurisdiction. In the absence of
local codes, installations shall comply with the following:

In the United States: The National Fuel Gas Code ANSI
Z223.1/NFPA 54. This publication is available from the
Canadian Standards Association, 8501 East Pleasant Valley
Rd, Cleveland Ohio 44131, or The National Fire Protection
Association, 1 Batterymarch Park, Quincy, MA 02269.

If after reading this manual you have any questions or do not
understand any portion of the instructions, call Maytag
Customer Service at 1-800-788-8899 for an authorized
servicer.

Carefully plan the place where you are going to put the water
heater. Correct combustion, vent action, and vent pipe
installation are very important in preventing death from
possible carbon monoxide poisoning and fires, see
figure 1 and 2.

Examine the location to ensure the water heater complies
with the Facts to Consider About the Location section in this
manual.

For California installation this water heater must be braced,
anchored, or strapped to avoid falling or moving during an
earthquake. See instructions for correct installation
procedures. Instructions may be obtained from your local
dealer, wholesaler, public utilities or California Office of the
State Architect, 400 P Street, Sacramento, CA 95814.

Massachusetts Code requires this water heater to be
installed in accordance with Massachusetts 248-CMR 2.00:
State Plumbing Code and 248-CMR 5.00. In the
Commonwealth of Massachusetts, this product must be
installed by a licensed plumber or gasfitter.

Complies with SCAQMD rule #1121 and districts having
equivalent NOx requirements.

CUSTOMER RESPONSIBILITIES

PRODUCT SPECIFICATIONS

* High altitude models have a B.T.U./Recovery Rate 10% less than shown.