Basket operation

The handles are removable so they can

be attached to the 2 small or 1 large
basket.

Location of basket to drain

With the lid open and in the vertical

position, the basket can be raised into the

rest draining position or removed
completely.

When in the draining position the basket

should be hooked on the basket rest lip
(shown by the arrow). When lowering the
basket back, lift up to remove from the
basket rest position, push forward slightly
and lower down. Press the basket release
button and allow the handle to lower.

When using the large single basket both

basket release buttons must be pressed to
allow the basket to lower into the oil.

Assembly/Disassembly
sequence

The fryer has to be disassembled and

assembled following this procedure.
• Open the lid and remove.
• Remove the basket.
• Lift out the tank.
• Pull out the pod control.

Assembly is the reverse of the above

process.

Removal of the pod

1 Lift up the fryer body at the front as

shown and pull out the pod.

2 Replace by locating the pod in the

guides and push fully in.

3 Once the pod is in place route the mains

cable to the side or out of the back,
whichever is convenient.

Replacing the bowl

Ensure bowl contacts are dry before

replacing.