Troubleshooting – Meco Assie Vantage LP 67c3c8kk81 User Manual

Page 31

Advertising
background image

31

Troubleshooting

Problem

Burners will not light
using a match

Low flame or low heat

Flames blow out

Possible Cause

Regulator coupling nut is not
fully connected to LP cylinder

LP-Excess flow valve tripped in
regulator

Vapor lock in connections

Obstructions in Burners

Wet Electrodes and Burners

Wire loose or disconnected

Wire shorting (sparking
between Igniter and Electrode)

Burners not assembled correctly

LP Gas Cylinder is empty

LP-Excess flow valve tripped in
regulator

Regulator Coupling nut is
not fully connected to LP Gas
Cylinder

Obstructions in Burners

LP-gas in LP Gas Cylinder is low

Excess flow valve tripped in
regulator

High or gusting winds

Gas in LP cylinder is low

Excess flow valve tripped

Solution

Tighten coupling nut by hand about one-half to three quar-
ters additional turn. Do not use tools.

Turn Control Knobs to “Off” position and turn LP Gas Cyl-
inder handle clockwise until it stops. Wait five minutes. Relight
LP gas grill. If flame continues to be low, turn off gas at LP Gas
Cylinder and grill. Disconnect the regulator from the LP Gas
Cylinder. Reconnect the regulator to the LP Gas Cylinder. This
will reset the excess flow valve Perform a leak test. Relight grill.

Clean the Burners. See “How to Clean Burners” in Care
and Maintenance.

Dry Electrode with clean cloth. Air dry or use blow dryer.

Reconnect the wire.

Replace Igniter Wire/Electrode assembly.
(Call the Customer Service Department)

See re-assembly after cleaning in Care and Maintenance.

Take LP Gas Cylinder to licensed LP gas supplier to be refilled.

Turn Control Knobs to “Off” position and turn LP Gas Cyl-
inder handle clockwise until it stops. Wait five minutes. Relight
LP gas grill. If flame continues to be low, turn off gas at LP Gas
Cylinder and grill. Disconnect the regulator from the LP Gas
Cylinder. Reconnect the regulator to the LP Gas Cylinder. This
will reset the excess flow valve Perform a leak test. Relight grill.

Tighten Regulator Coupling nut by hand about one-half to
three quarters additional turn. Do not use tools.

See “How to Clean Burners” in Care and Maintenance.

Check LP Gas Cylinder. Refill if necessary.

Turn Control Knobs to “Off” position and turn LP Gas Cyl-
inder handle clockwise until it stops. Wait five minutes. Relight
LP gas grill. If flame continues to be low, turn off gas at LP Gas
Cylinder and grill. Disconnect the regulator from the LP Gas
Cylinder. Reconnect the regulator to the LP Gas Cylinder. This
will reset the excess flow valve Perform a leak test. Relight grill.

Turn front of grill away from wind or increase flame height.

Check LP Gas Cylinder. Refill if necessary.

See “Low flame” problem above.

Advertising