MINIMUM HEARTH DIMENSIONS

GENERAL INSTALLATION INFORMATION

Figure 2 - Minimum Hearth Dimensions

Carefully select the best location for installation of your
vent-free firebox. The following factors should be taken
into consideration:
• Clearance to side wall, ceiling, woodwork and windows.

See “Clearances/Height Requirements on page 8.
Minimum clearances to combustibles must be main-
tained.

• Location must not be affected by drafts caused by

kitchen exhaust fans, ceiling fans, return air registers
for forced air furnaces / air conditioners, windows or
doors.

• Installation must provide adequate ventilation and

combustion air.

• DO NOT INSTALL THIS FIREBOX IN A BEDROOM

OR BATHROOM.

• Location should be out of high traffic or windy or drafty

areas.

• DO NOT INSTALL WHERE CURTAINS, FURNITURE, CLOTHING OR OTHER FLAMMABLE OBJECTS

ARE LESS THAN 42" FROM FRONT OF HEATER.

• Never obstruct the front opening of the vent-free firebox or restrict the flow of combustion and ventilation

air.

• Minimize modifications to existing construction. Refer to Figure 3 below for location suggestions.
• Do not install in the vicinity where gasoline or other flammable liquids may be stored. The vent-free firebox

must be kept clear and free from these combustible materials.

LOCATION OF FIREBOX