4 AT Commands, S-Registers, and Result Codes

30

Command:

&E

n

V.42bis Data Compression

Values:

n = 14 or 15

Default:

15

Description:

&E14 V.42bis data compression disabled.
&E15 V.42bis data compression enabled.

Note:

This command controls only V.42bis data compression,

whereas the %C command controls both V.42bis and MNP-5
data compression. The command in effect is the one last en-
tered. See also the L5 command.

Command:

&F

n

Load Factory Settings

Values:

n = 0 or 1

Default:

None

Description:

&F0

Load factory configuration 0.

&F1

Load factory configuration 1.

Note:

See also the Z, L5, and &V commands.

Command:

&G

n V.22bis Guard Tone Control

Values:

n = 0, 1, or 2

Default:

0

Description:

&G0 Disable guard tone.
&G1 Set guard tone to 550 Hz.
&G2 Set guard tone to 1800 Hz.

Note:

The &G command is not used in North America, and

may not be permitted in some countries.

Command:

&J

n

Telephone Jack Control

Values:

n = 0 or 1

Default:

None

Description:

&J0

NA

&J1

NA

Note:

This command is included only for backwards compati-

bility. It performs no function except to load the S-register. The
parameter value, if valid, is written to S21 bit 1.

Command:

&K

n Flow Control Selection

Values:

n = 0, 3, 4, 5, or 6

Defaults:

3 (data modem mode)
6 (fax modem and voice modes)

Description:

&K0 Disables flow control.
&K3 Enables CTS/RTS hardware flow control.
&K4 Enables XON/XOFF software flow control.
&K5 Enables transparent XON/XOFF flow control.
&K6 Enables both RTS/CTS and XON/XOFF flow control.

Note:

See also the &E command