Thermostat

High quality water temperature control thermostat, adjustable from 9°C to 15°C (48°F to
60ºF).

Pilot Light

Twin pilot lights to indicate power supply and compressor operation.

Voltage Rating

All models operate on 220/240 Volts, 50/60 cycles single phase A.C. supply.

Water Filtration

A ceramic cartridge type water filter is also available as an option.

Water Filter

MECO Water Purifying Systems are available as an option.

Periodic Cleaning and Maintenance

1) Prior to installation, remove back cover of cooler and visually inspect for transit

damage. Temporarily connect cooler to electric supply and switch on the
thermostat. Check that fan is operating and not jammed.

2) Please switch off the electric power to the cooler before performing any cleaning

or maintenance

3) If the wastewater drain is blocked during use, remove the drain try and clean

drain pot. Then remove blockage by flushing water under pressure through the
drain hole.

4) After removing back cover, dust out the condenser by blowing air under

pressure. This cleaning should be performed at least once a year or more
frequently if loss in cooling occurs.

5) While back cover is removed, check that green or yellow earth wire is secured

tightly to cooler base.

6) For transportation of cooler and during periods when the cooler is not in use,

empty the water from tank by first removing the back cover and then opening the
drain plug. In case there is no drain plug (if the tank is made of stainless steel),
apply air under pressure to the inlet and open taps to drain water.

7)

Keep the cabinet of the cooler dry to prevent damage due to rust. Wipe off any
water spills as soon as possible to protect the base. For added safety, the cooler
can be placed on wooden base.