background image

To extinguish flame / Turn off gas flow
From Normal Use: Release pressure from ignition button. Unit will shut

off immediately. (figure 2)

From Hands free use: Slide hands free slide stem to full left position.

Unit will shut off immediately (figure 3).

CAUTION:
1. Keep out of reach of children.
2. Do not touch flame guard when hot!
3. Butane gas is extremely flammable, please handle with care.
4. Always point away from eyes and body when igniting

or operating.

5. Do not store under direct sunlight or anywhere that will exceed

104°F/40°C.

6. Under no circumstances should you attempt to repair a damaged torch.
7. After using, let the tool cool down before storing.

Contains flammable gas under pressure. Do not use near sparks or open
flame. Do not puncture or incinerate container.

To refuel unit. (figure 1)
• Make sure the unit is OFF and COOL to touch.
• Make sure the protective cap is on nozzle.
• Use only Master Ultratane

®

butane to refuel unit, hold unit firmly with

filler valve pointing up. Place nozzle of butane canister down onto refill
valve and press butane canister down and up in short duration until fuel
tank is filled. Allow 2 -3 minutes for gas to stabilize after filling unit.

• Flame is invisible in direct sunlight. Use caution.
• Point away from face and body when igniting.
• Use in well ventilated areas.
• Always have a fire extinguisher/ bucket of water nearby work area.
• The tank contents are visible through the clear viewing port on the unit.

Designers and Manufacturers of Heat Tools

MICROTORCH MT-5

Size dim.

75x32x21mm

Unit Weight

45g

Internal tank pressure

65 g/mm2 max

Continuous burn time

20 min. - one fill

Specifications

CAP

SAFETY LOCKOUT

LEVER

BODY

FUEL VIEW

WINDSHIELD

IGNITION BUTTON

FLAME ADJUSTMENT

To ignite unit (figure 2)
• Remove safety cap.
• Slide lockout lever to off position and hold in position while slowly

depressing ignition button.

• After a few attempts if no flame appears, fine tune the unit’s gas flow

and retry ignition step above.

To adjust fuel flow (figure 4)
• Adjust the unit fuel flow by turning the black fuel flow adjustment wheel

at bottom of unit. A 1/4 inch turn CW/CCW will usually be all that is
needed. Note: Extreme caution must be taken not to over adjust fuel
flow. If you are unable to make proper adjustment, please call customer
service. As the gas is consumed, the gas flow can be adjusted periodi-
cally to ensure proper flame height. It is recommended that the user set
the flame height to 1/2 inch to 1 inch. If the flame height is set outside
these limits the fuel flow / flame may become unstable and cause
premature clogging or ignition failure.

Hands free mode (figure 3)
• To engage hands free mode follow ignition steps above and once the

unit is ignited, position slide stem button (found on backside of unit) to
full right position. This will allow hands free operation of unit.

Fig. 1

Fig. 3

OFF-LOCK

Please read and understand
all warnings and instructions.

2420-18th Street, Racine, WI 53403 U.S.A.
PHONE: 262-633-7791 FAX: 262-633-9745
www.masterappliance.com
E-mail: [email protected]

MORE

GAS

LESS

GAS

BOTTOM VIEW

GAS FLOW VALVE STEM

FUEL ADJUSTMENT

Fig. 2

Fig. 4