Rebuild Instructions

Disassembly

Verify that no ice is in the auger/barrel (refer to Figure 1 on Sheet 2.

1.

Remove splined hub.

2.

Remove key stock. Sand shaft smooth where setscrew contacted shaft.

3.

Remove evaporator top cap and grease from top of evaporator.

4.

Remove top snap ring (big clip). (QF2300 only - also remove spring shim.)

5.

Drive auger shaft out through top of evaporator by placing a wooden 2 x 4 on the floor and tapping the auger shaft
on the 2 x 4.

6.

Remove run-out collar (remove from bottom, or run-out collar will be on the auger).

7.

Remove bottom shaft seal.

8.

Remove lower bearing snap ring. (QF2300 only - also remove bearing shim.)

9.

Drive out bottom bearing (QF2300 only - also drive out second bearing shim) with bearing removal tool (top to
bottom).

10.

Remove water seal snap ring.

11.

Remove water seal (top to bottom).

12.

Remove snap ring from top of auger.

13.

Remove top bearing with a bearing puller.

14.

Remove top seal.

Cleaning after Disassembly

Inspect auger and check for damage to the following areas:

Top bearing seat
Top shaft seal area
Bottom bearing seat

Bottom seal area

Remove contamination from auger:

Clean the following with 460 grit emery cloths:
Auger

shaft

Auger flights (both sides - top and bottom)

Do not clean the cutting head with sandpaper (flakers only):

The cutting head self-cleans due to ice shear - emery cloth will dull the cutting edge.

Sand the auger with emery cloth until all scale is removed.

Evaporator barrel cleaning:

Assemble wheel stack on mandrel.
Drill and shaft extension are required:

Use speeds less than 200 rpm, slower = better.
Keep moving up and down; do not stop in one spot.

Scotch-Brite disc for cleaning:

Disc must be larger than inside diameter of barrel for even contact:

2" disc used on models QF0400, QC0700, and QF0800

4" disc used on models QF2300

Clean thoroughly with multiple passes of disc and clean cloths.

Thoroughly clean water inlet and ice outlet to complete the cleaning of the barrel.

Manitowoc Ice, Inc.

2110 South 26

th

Street, P.O. Box 1720, Manitowoc, WI 54221-1720 USA

8014373

Telephone 920-682-0161, Fax - Sales: 920-683-7589, Service/Parts: 920-683-7585, Other: 920-683-7879 Sheet 1 of 2
Web Site - www.manitowocice.com