You can have either two or three links to each peripheral bay:

•

With a MCCIIIEL / ELx control card, the Control Dual FIM Carrier card or the Control Triple
CIM card provides three links per peripheral bay

•

With an MCCIIIEL control card, the Control Triple FIM Carrier card or the Control Triple
CIM card provides two links per peripheral bay

•

With an MCCIIIELx control card (installed in a SX-200 ELx cabinet PN 9109-600-002-NA)
the Triple FIM Carrier card or the Control Triple CIM card provides three links per peripheral
bay.

If you provide two links to each bay:

•

You can have a maximum of seven cabinets in the system

•

Prior to LIGHTWARE 18 Release 2.0, you could have one bay with two T1 trunk cards
and the other bays with one T1 trunk card to total a maximum of seven T1 trunk cards in
the system

•

With LIGHTWARE 18 Release 2.0 or greater, you can have a total of 8 T1 links in the
system with a maximum of 2 T1 links per bay

•

If a T1 trunk card is installed in slot 10 of a bay, you cannot install a peripheral interface
cards in slot 5; if a T1 trunk card is installed in slot 11, you cannot install a peripheral
interface card in slot 6

•

T1 links from a T1/E1 module on a BCC III also occupy slots 5 and 6 in software only

•

Calls must be evenly distributed across all bays

•

Maximum channel blocking ratio is 0.58.

If you provide three links to each bay

•

You can have a maximum of seven cabinets in the system

•

Prior to LIGHTWARE 18 Release 2.0, you could have one bay with two T1 trunk cards
and the other bays with one T1 trunk card to total a maximum of seven T1 trunk cards in
the system.

•

With LIGHTWARE 18 Release 2.0 or greater, you can have a total of 8 T1 links in the
system with a maximum of 2 T1 links per bay.

•

If a T1 trunk card is installed in slot 10 of a bay, you cannot install a peripheral interface
cards in slot 5; if a T1 trunk card is installed in slot 11, you cannot install a peripheral
interface card in slot 6.

•

T1 links from a T1/E1 module on a BCC III also occupy slots 5 and 6 in software only.

Note: A manual switch on the Control Triple CIM card controls whether the card will
emulate a Control Dual FIM Carrier card or a Control Triple FIM Carrier card.

Note: As a guideline to achieve a P.0001 grade of service (one failure in 10,000 calls)
for a Bay connected via a Control Triple FIM Carrier, the recommended maximum
calls/hour is 500 based on traffic tables. With a typical call hold time of 2 minutes and 12
seconds the total Erlang rate is 18.33 (660 CCS) for the whole Bay. The half Bay would
therefore be 9.17 Erlangs (330 CCS) at 250 calls/hour. It is important that calls be evenly
distributed across all Bays.