Flake ice machines refrigeration system – Ice-O-Matic EMF Series User Manual

Page 44

Advertising
background image

Flake Ice Machines

Refrigeration System

Page

F3


Refrigerant Pressures (Continued)
The operating pressures for models utilizing the Alco thermostatic expansion valve are
listed below.

ALCO Manufactured Expansion Valve

Model

Air

Water

Suction

Discharge Pressure PSIG

Number

Temp °F

Temp °F

Pressure PSIG

192 LAC

240 LAC

EMF2306R

90°F

70°F

40

265

266

70°F

50°F

35

217

260

-20°F/50°F

40°F

33

200

263

120°F/110°F

100°F

45

365

355

EMF2306W

90°F

70°F

38

250

70°F

50°F

37

250

50°F

40°F

36

250

110°F

100°F

42

250

EMF405A

90°F

70°F

56

274

70°F

50°F

53

215

50°F

40°F

36

158

110°F

100°F

61

352

EMF450A

90°F

70°F

56

290

70°F

50°F

52

222

50°F

40°F

51

131

110°F

100°F

57

374

EMF450W

90°F

70°F

50

250

70°F

50°F

48

250

50°F

40°F

46

250

110°F

100°F

54

250


Advertising