Operating your therapure® 300d, Cleaning & maintenance – Ionic Pro 1040808 User Manual

Page 6

Advertising
background image

8

300

9

operating your therapure® 300d

DIGITal DISPlaY

1. Fan Speed Indicator

The first bar is lit when the fan speed is on QuIET. The first two bars are lit when the fan

speed is loW. The first three bars are lit when the fan speed is MEDIuM. When all four

bars are lit, the fan speed is hIGh.

Therapure’s powerful, yet quiet, 4-speed fan let’s you determine your desired sanitizing

level. Simply select your desired setting and the fan draws in the contaminated air in front

of your Therapure

®

300D air purifier and starts sanitizing.

The 4 speeds are Quiet, Low, Medium or High. The speed you set determines how rapidly

you want to sanitize the air. The “loW” setting is great for day in, day out use. The

MEDIuM” setting is great for areas with more airborne contaminants (such as excessive

smoke, pet dander, etc), or areas used frequently by allergy-sufferers. The “hIGh” setting is

best used for shorter bursts of time when you want to rapidly sanitize the air. “QuIET” is for

the most silent low speed operation.

2. Timer Indicator

The digit of the timer indicates the hour(s) preset. Once the time is set, the timer will start

to count down to zero and the unit will then automatically turn off.

3. Ion Indicator

The ion light turns on when the ionizer is working and the light turns off when the

ionizer stops.

4. uV/VoC

cleaning & maintenance

Before cleaning or replacing the

permanent HEPA-type filter or UV lamp

of your Therapure

®

300D air purifier,

turn off and unplug the unit from the

electrical outlet and read all safety

instructions and important warnings in

this owner’s manual.

ClEanInG ThE

ThERaPuRE

®

300D

Cleaning the Permanent

hEPa-Type Filter
1.
Make sure unit is turned off and

unplugged. With the front of the

unit facing up, pull up the lower

end of the inlet grill as shown below.

2. After pulling up, push the inlet

grill toward the display panel at

the top of the unit.

3. Remove the permanent filter by

lifting and pulling the string.

4. Clean the filter after every

200-300 hours of use, or more

often if unit is used more frequently

or if air quality is poor. The filter

can be cleaned with a vacuum. After

cleaning and re-inserting the filter,

put inlet grill back on the front of

the unit or clean inlet grill as

described below and then put

it back in its original position before

resuming use.

5 . Clean the inlet grill after every

200-300 hours of use, or you can

clean it more frequently if unit is

placed in an area with a high level

of airborne irritants. The inlet grill

can be cleaned with a vacuum

or a piece of damp cloth. When

finished cleaning, insert the

top of the inlet grill first and then

snap the lower part of the inlet

grill back into position.

1.

5.

4.

Pull

String

3.

2.

1. Fan Speed

Indicator

2. Timer Indicator

3. Ion

4. uV/VoC