IFoundry Systems IFSYS-5651 MSP430 User Manual
Page 26

Page 26 of 50
Copyright © 2008 iFoundry Systems
IFSYS-5651 MSP430 Bluetooth Evaluation Kit User Guide
Prior to connecting anything up or powering on the IFSYS-5651 board, ensure the
following procedures have been carried out:
• Configure jumpers as follows:
•
5043CONN jumper is set to EXT (installed on pins 2-3) – this connects the
IFSYS-5043 to the RS232 at P3 instead of MSP430 microcontroller
•
LEDSEL jumper is set to 5043 position (installed on pins 2-3) – this allows LED1
and LED2 to be controlled by the IFSYS-5043,
•
MODE jumper is set to NORM position (installed on pins 1-2)
• As part of program development, you will need to eventually download your code to
the IFSYS-5043 module. Section 9 - DOWNLOADING FIRMWARE TO IFSYS-5043
BLUETOOTH MODULE describes the procedure for doing this.