Starting the collection of affinity data – IBM Transaction Server OS User Manual

Page 49

Advertising
background image

5

The total number of affinity records in the affinity data VSAM files. If the

Detector was stopped by CICS crashing, and was in the middle of saving affinity
data, this figure may be inaccurate. However, the figure is corrected the next time
the Detector is started.

6

The date and time when the Detector was last started, data was saved, and a

change was made to an affinity table. The date is given in the format specified by
the DATFORM system initialization parameter.

7

The total time that the Detector has been in the running and paused states

since it was last started.

8

The name, and current percentage occupied, of the MVS dataspace being

used. (This is not displayed while in STOPPED state.)

9

The message line used to display diagnostic messages.

10

The keys that you can use to select functions to affect the operation of the

Detector, or to get help information about it. This line displays all possible functions,
not all of which are appropriate (or selectable) for a given state of the Detector.

Starting the collection of affinity data

When you can start collecting affinity data

You can start collecting affinity data only when the Detector is currently
stopped.

To start collecting affinity data, use one of the methods shown in Table 3.

Table 3. Methods for starting data collection by the Detector

Where used

Command or function key

Control display, CAFF01

F5 function key

1

3270 terminal

CAFF START

Console

F cicsjob, CAFF START

2

Application program

EXEC CICS START TRANSID(’CAFF’) FROM(’START’)

3

Notes:

1

If you press the F5 function key of the CAFF01 screen, you are asked to

confirm that you want to start the recording of affinity data.

2

cicsjob is the name of your CICS startup job.

3

You can use this command from a program initiated during the third stage of

CICS initialization: that is, a program specified in the second part of the PLTPI list
for the CICS region. For more information about using PLTPI programs, see the
CICS Customization Guide.

Using one of the methods listed in Table 3 causes the Detector to record
transaction affinities in the CICS region, until you pause or stop data collection by
the Detector. Data is collected for only the affinity types that you have chosen to be
detected (by specifying Y for the affinity type on the CAFF02 screen).

Chapter 5. Running the Detector