Electrical Installation Requirements - Model IHC030

Only trained personnel should perform this

procedure. Use caution while servicing

machines with covers removed and power

applied.

W700

WARNING

Boiler Fed/Steam Heat

Electric Heat

Code

Vo
lta

g

e

Cycle

Phase

Wi
re

Full Load

Amp

s

Recommended

Circ

uit Brea

ker

(US-market)

AW
G

/m

m

2

kW S

tand
a

rd

Hea

ting Elemen

ts

Full Load

Amp

s

Recommended

Circ

uit Brea

ker

(US-market)

AW
G

/m

m

2

US NON-US

US

NON-US

N 440-480

50/60

3

3+PE

6

15

10

14/2.5

6x2 kW

23

30

32

10/6.0

P

380-415

50/60

3

3+N+PE

18

20

20

12/4.0

36

40

40

8/10.0

Q 200-240

50/60

3

3+PE

18

20

20

12/4.0

49

60

60

6/16.0

X 200-240

50/60

1/3

2/3+PE

18

20

20

12/4.0

N/A

N/A

N/A

N/A

Alternative Electric Heat Options

N 440-480

50/60

3

3+PE

3x3 kW

+

3x2 kW

28

40

40

8/10.0

P

380-415

50/60

3

3+N+PE

40

50

50

8/10.0

Q 200-240

50/60

3

3+PE

56

60

60

6/16.0

X 200-240

50/60

1/3

2/3+PE

56

60

60

6/16.0

N 440-480

50/60

3

3+PE

6x3 kW

32

40

40

8/10.0

P

380-415

50/60

3

3+N+PE

44

50

50

8/10.0

Q 200-240

50/60

3

3+PE

63

70

70

4/25.00

X 200-240

50/60

1/3

2/3+PE

63

70

70

4/25.00

N 440-480

50/60

3

3+PE

3x3 kW

+

3x4 kW

36

40

40

8/10.0

P

380-415

50/60

3

3+N+PE

49

60

60

6/16.0

Q 200-240

50/60

3

3+PE

N/A

N/A

N/A

N/A

X 200-240

50/60

1/3

2/3+PE

N/A

N/A

N/A

N/A

N 440-480

50/60

3

3+PE

6x4 kW

41

50

50

8/10.0

P

380-415

50/60

3

3+N+PE

53

60

60

6/16.0

Q 200-240

50/60

3

3+PE

N/A

N/A

N/A

N/A

X 200-240

50/60

1/3

2/3+PE

N/A

N/A

N/A

N/A

Table 4