Trouble-shooting – Ionic Pro CA500 User Manual

Page 8

Advertising
background image

13

TROUBLE-SHOOTING

12

CLEANING & MAINTENANCE

Deep Cleaning

Noisy functioning (audible loud buzzing sound) is a sign that your Ionic Pro

®

ionic air purifier is overdue for a complete clean-up of the collection blades and
the internal ionizing wires. The internal ionizing wires must be kept clean to
ensure silent and normal operation.

For deep cleaning, follow both the

“TO CLEAN THE COLLECTION BLADES”

&

“TO CLEAN IONIZING WIRES”

sections.

IMPORTANT: MAKE SURE THE THOROUGHLY CLEANED AND DRIED COLLECTION BLADES ARE PROPERLY
INSERTED, THE REMOVABLE CAP IS BACK IN ITS ORIGINAL POSITION, AND THE WIRE CLEANING MECHANISM
IS BACK IN ITS ORIGINAL POSITION BEFORE RESUMING USE—OR THE UNIT WILL NOT FUNCTION.

Cleaning External Surfaces

Over time, some particles and dust may accumulate on the external surfaces of
your Ionic Pro

®

ionic air purifier. If this happens, turn off and unplug the unit. Mix

one ounce of laundry bleach with five ounces of water and apply sparingly with a
sponge to wipe the outer case surfaces. Do not allow water to slip into the internal
parts of the Ionic Pro

®

ionic air purifier as this could damage its functioning and

may result in injury to you. Allow the unit to dry for at least 24 hours before
resuming use.

TROUBLE-SHOOTING

*See “Cleaning & Maintenance” section

TROUBLE

Indication/Setting light
not on

Red CLEAN light is on

Excessive noise
generated*

Collection blades do not
go back in

Indication light does not
go on

REASON

Machine is unplugged.
ON/OFF button has not
been pressed.

Too much dust has
accumulated.

Collection blades
are jarred or removed
suddenly.

Red light may go on
if the unit just needs
to be “reset”.

Too much dust has
accumulated or internal
parts are wet.

Improper blade orientation

Collection blades are not
completely inserted.

Wire Cleaning Mechanism is
not completely inserted

TROUBLE-SHOOTING

Check if plug is loose.
Press the ON/OFF
button.

Turn off, unplug and clean
using instructions from the
“Deep Cleaning” section.

Remove and re-insert
collection blades
and press "on"
button to reset.

Press “on” button to reset.

Clean and dry blades
and ionizing wires
thoroughly*. Keep the
machine dry.

Reverse blade orientation

Check to see that the
blades are completely
seated in housing.

Check to see that Wire
Cleaning Mechanism
is completely seated in
housing.

IP_CA500_Mnl_Rev_092707.qxp:Layout 1 6/3/08 2:56 PM Page 14

Advertising