Installation - model ihf165 – IPSO CHM2172N User Manual

Page 26

Advertising
background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Washer-Extractors

5-08-53

25

Installation - Model IHF165

Ground

The machine must be placed on a flat, solid surface

(metal base, concrete or solid ground). It is

recommended that the machine be anchored (M16) on

the provided places (1) in the base, especially in case

of a plinth (See Mounting Bolt Hole Locations). Refer

to Figure 17.

Figure 17

The machine must be placed entirely level. For easy

maintenance it is recommended to keep a minimal

distance of 23.62 in. (600 mm) between the wall and

the back of the machine.
If several machines are placed next to each other, there

should be a minimal distance of 1.18 in. (30 mm)

between each machine.

Electrical Installation Requirements
- Model IHF165

Table 4

CHM2180N

1

Mounting Bolt Holes

1

Machine without electrical heating

240V 3AC

400V 3AC + N

40 A

25 A

Machine with electrical heating

240V 3AC

400V 3AC + N

27 kW

125 A

63 A

36 kW

N/A

80 A

Advertising