Tumblers – 50 and 75

20

4-08-44

50 and 75 Pound Electric Models

Refer to Table 6.

NOTE: Wire size and breaker ratings were

obtained from the Canadian Electrical Code for

75 C. wire and are intended for use as a guideline

only. Electrical connections should be made by a

qualified electrical contractor in accordance with

all applicable local and national requirements.

NOTE: Electrical specifications below are subject

to change without notice. Always refer to product

serial plate for most current specifications of

product being installed.

NOTE: Use copper conductors only.

NOTE: Connect to individual branch circuit.

NOTE: 3 Phase Only – Each tumbler must be

connected to its own individual branch circuit

breaker, not fuses, to avoid the possibility of “single

phasing” and causing premature failure of the

motor(s).

Serial Plate Rating

Terminal Block

Connections

Required

Serial Plate Amps

Recommended Circuit

Nonreversing

Reversing

Breaker

Rating

Wire Size

AWG (mm

2

)

240V/50Hz/1ph

(50 Pound only)

L1, Neutral and Ground

93

95

125A – 1 pole

1 (42.4)

200-208V/60Hz/3ph

L1, L2, L3 and ground

89

88

125A – 3 pole

1 (42.4)

200V/50Hz/3ph

L1, L2, L3 and ground

84

85

125A – 3 pole

1 (42.4)

230V/50Hz/3ph

L1, L2, L3 and ground

73

75

100A – 3 pole

3 (26.7)

240V/50Hz/3ph

L1, L2, L3 and ground

79

78

100A – 3 pole

3 (26.7)

240V/60Hz/3ph

L1, L2, L3 and ground

79

78

100A – 3 pole

3 (26.7)

380V/50 or 60Hz/3ph

L1, L2, L3 and ground

47

48

60A – 3 pole

6 (13.3)

400-415V/50Hz/3ph

L1, L2, L3 and ground

43

44

60A – 3 pole

6 (13.3)

440V/60Hz/3ph

L1, L2, L3 and ground

41

41

51A – 3 pole

6 (13.3)

480V/60Hz/3ph

L1, L2, L3 and ground

38

38

50A – 3 pole

6 (13.3)

Table 6