Control cable signals, Terminal information, Start voltage [star – Icom AT-140 User Manual

Page 9: Key voltage [key

Advertising
background image

3

6

CONTROL CABLE SIGNALS

Terminal information

Consider the following points when using a non-Icom
transceiver.

Start voltage [STAR]

When a start voltage (less than 1 V) is received, the
AT-140 begins automatic tuning.

Key voltage [KEY]

During automatic tuning, the AT-140 grounds the key
voltage line, and the HF transceiver reduces output
power.

If the key voltage is more than 8 V, switch the mode
switch (S1) to OFF mode (lower position).

8

6

4

2

0

Time

Key
voltage
[V]

Grounded

Approx. 7.5 V

During automatic tuning

8

6

4

2

0

Time

More than
350 msec.*

Approx. 7.5 V

Less than 1 V to
start tuning

Start
voltage
[V]

*For tuner through operation; Less than 250 msec.

[KEY]
[STAR]
[13.6]
[E]

Terminal

Description

[KEY]

Key voltage. Grounded during tuning.
Max. current drain 100 mA.

[13.6]

13.6 V DC

+

input terminal.

Max. current drain 2 A

[STAR]

Receives start voltage.
Max. current drain 1 mA

[E]

Ground terminal for above signals.

Mode switch (S1)

[E]

[13.6]

[STAR]

[KEY]

NORMAL mode

OFF mode

S1

Advertising