Trouble shooting, Dimensional data – Ingersoll-Rand 650717-C User Manual

Page 8

Advertising
background image

650717ĆC

Page 8 of 8

TROUBLE SHOOTING

Product discharged from exhaust outlet.

S

Check for diaphragm rupture.

S

Check tightness of diaphragm nut.

Air bubbles in product discharge.

S

Check connections of suction plumbing.

S

Check O" rings between intake manifold and fluid caps.

S

Check tightness of diaphragm nut.

Low output volume, erratic flow or no flow.

S

Check air supply.

S

Check for plugged outlet hose.

S

Check for kinked (restrictive) outlet material hose.

S

Check for kinked (restrictive) or collapsed inlet material hose.

S

Check for pump cavitation Ć suction pipe should be sized at least as

large as the inlet thread diameter of the pump for proper flow if high

viscosity fluids are being pumped. Suction hose must be a nonĆcolĆ

lapsing type, capable of pulling a high vacuum.

S

Check all joints on the inlet manifolds and suction connections.

These must be air tight.

S

Inspect the pump for solid objects logged in the diaphragm chamber

or the seat area.

DIMENSIONAL DATA

Dimensions shown are for reference only, they are displayed in inches and millimeters (mm).

8Ć1/2"

(216 mm)

11Ć9/16"

(294 mm)

12Ć1/2"

(318 mm)

7Ć5/16"

(186 mm)

1Ć1/4"

(32 mm)

6Ć1/4"

(159 mm)

13/32"

(10 mm)

Slot

Figure 4

6Ć1/2"

(165 mm)

4"

(102 mm)

8"

(203 mm)

Air Inlet

(1/4 Ć 18 N.P.T.)

Material Outlet

(1 Ć 11Ć1/2 N.P.T.F. Ć 1)

Material Inlet

(1 Ć 11Ć1/2 N.P.T.F. Ć 1)

Pressure Relief Valve (1/4 Ć 18 N.P.T.)

PN 97999Ć1065

Advertising