Intelligent Motion Systems IM1007 I/IE User Manual

Page 29

Advertising
background image

24

Cable length, wire gauge and power conditioning devices play a major role

in the performance of your IMS Driver and Motor.

NOTE: The length of the DC power supply cable between the IMS Driver

and the Motor should not exceed 50 feet.

Example A demonstrates the recommended cable configuration for the IMS

Driver to Motor cabling under 50 Feet long. If cabling of 50 feet or longer is
required, the additional length can be gained with the cable configuration in
Example B.

Correct AWG wire size is determined by the current requirement plus cable

length. Please see the IMS Driver to Motor Cable AWG Table in this Appendix.

Shield to Earth Ground

on Supply End Only

Two Shielded/Twisted Pairs

(Wire Size from

IMS Driver to Motor Cable AWG Table)

Braided

Shield

Ferrite

Beads

Cable Length

less than 50 Feet

Phase A
Phase A
Phase B
Phase B

Phase A

Phase A

Phase B

Phase B

E x a m p l e A - C a b l i n g U n d e r 5 0 F e e t ,
I M S D r i v e r t o M o t o r

R e c o m m e n d e d C a b l e C o n f i g u r a t i o n s :

I M S D r i v e r t o M o t o r

Advertising