Function-Related Symptoms

Symptom / Error

FRU / A

CTION IN

S

EQUENCE

The system does not
suspend or resume when the
LCD is closed or opened.

1.

Go to “Suspend Mode”
on page 20, and check
that the WorkPad z50
can enter suspend
mode.

2. LCD

panel

3.

Mainboard

The memory count (size)
appears different from actual
size.

Go to “Memory Checkout” on
page 8.

The system hangs
intermittently.

Go to “Intermittent Problems”
on page 26.

Indicator-Related Symptoms

Symptom / Error

FRU / Action in Sequence

The indicator incorrectly
remains off or on, but system
runs correctly.

Mainboard

The external/power status
LED indicator blinks from
green to amber.

1.

Check that a correct
battery is installed.

2. Battery

pack

3.

Mainboard

The battery indicator does not
turn on when the battery is
installed.

1. Battery

pack

2.

Mainboard

Infrared-Related Symptoms

Symptom / Error

FRU / Action in Sequence

Unable to communicate using
the Infrared (IR) Port.

1.

Make sure the setup for
the IR is correct. Use
the WorkPad z50
Configuration utility.

2.

Make sure there are no
fluorescent lights near the
WorkPad z50. The
WorkPad z50 may receive
optical noise from the
fluorescent light.

3.

Run the advanced
diagnostic test. If an error
occurs, replace the parts
shown by the FRU code.