21

5

OTHER FUNCTIONS

New master

Monitor audible function

The monitor function allows you to open the transceiver’s squelch
manually to check whether a channel is busy or not. The trans-
ceiver has 2 conditions for receive standby:

• Audible condition:

This condition mutes audio ONLY when

no carrier is present. You can receive (or
monitor) any signals on a channel.
• Push and hold the [MONI] switch to can-

cel the CTCSS or DTCS tone squelch
function.

Any audio mute functions are cancelled
while pushing the [MONI] switch.

• Inaudible condition: This condition
mutes ALL signals except those directed
to you. Therefore you should check a
channel’s condition (busy or not) with the
monitor function before transmitting.

• Push the [MONI] switch momentarily to
select the inaudible condition.

Time-Out Timer

The transceiver has time-out timer function. This function prevents
continuous, extend transmissions. This timer automatically turns a
transmission OFF 3 min. after it starts.
A warning beep emits 10 sec. before the limit is reached.
The end beep emits 5 times to announce the end of the transmis-
sion.

All signals are
received

Only signals con-
taining the proper
tone are received

IC-F22SR-(1) 02.3.23 2:29 PM Page 26 (1,1)