Trouble shooting, Dimensional data – Ingersoll-Rand ARO 650718-C User Manual

Page 8

Advertising
background image

Page 8 of 8

650718-C (en)

PN 97999-1064

TROUBLE SHOOTING

Product discharged from exhaust outlet.

Check for diaphragm rupture.
Check tightness of (14) diaphragm screw.

Air bubbles in product discharge.

Check connections of suction plumbing.
Check “O” rings between intake manifolds and fl uid caps.
Check tightness of (14) diaphragm screw.

y

y

y

y

y

Low output volume, erratic fl ow or no fl ow.

Check air supply.
Check for plugged outlet hose.
Check for kinked (restrictive) outlet material hose.
Check for kinked (restrictive) or collapsed inlet material
hose.
Check for pump cavitation - suction pipe should be sized
at least as large as the inlet thread diameter of the pump
for proper fl ow if high viscosity fl uids are being pumped.
Suction hose must be a non-collapsing type, capable of
pulling a high vacuum.
Check all joints on the intake manifolds and suction con-
nections. These must be air tight.
Inspect the pump for solid objects lodged in the dia-
phragm chamber or the seat area.

y

y

y

y

y

y

y

DIMENSIONAL DATA

Dimensions shown are for reference only, they are displayed in inches and millimeters (mm).

Figure 5

A

G

C

D

E

B

F

H

J

K

L

P

(air exhaust)

M

(material inlet)

M

(material outlet)

N

(air inlet)

Q

(pressure relief valve)

DIMENSIONS

A - 13-1/8” (333.4 mm)
B - 18-3/8” (466.7 mm)
C - 9” (228.6 mm)
D - 2-3/4” (69.9 mm)
E - 14-13/16” (376.2 mm)

F - 11-1/2” (292.1 mm)
G - 19-5/8” (498.5 mm)
H - 1

0-3/4” (273 mm)

J - 12” (3

05mm)

K - 17/32” (13.5 mm)

L - 7-5/8” (193.7 mm)
M - 1-1/2 - 11-1/2 N.P.T.F. - 1
N - 1/2 - 14 N.P.T.F. - 1
P - 3/4 - 14 N.P.T.F. - 1
Q - 1/4 - 18 N.P.T.

Advertising