Required fixes – IBM WEBSPHERE 6.1.X User Manual

Page 56

Advertising
background image

5 1

W E B S P H E R E P O R T A L V 6 . 1 T U N I N G G U I D E

IBM Tivoli Directory Server Tuning

The following table shows the tuning values used for the directory servers.

How-to-Set: These values are in the file /opt/IBM/ldap/V6.0/etc/SchemaV6.0/ibmslapd.conf. You
must restart the LDAP server after changing these values.

Table 28: IDS Tuning in Vertical Cluster

Parameter

Setting Used

Ibm-slapdACLCacheSize

250000

Ibm-slapdEntryCacheSize

250000

Ibm-slapdFilterCacheSize

250000

Ibm-slapdFilterCacheBypassLimit

7500

The IBM Tivoli Directory Server uses IBM DB2 as the database server. The database
instance and alias are named IDSLDAP. We applied the following tuning to this database:

db2 “update db config for idsldap using dbheap 4800”

db2 “update db config for idsldap using num_iocleaners 5”

db2 “update db config for idsldap using num_ioservers 10”

db2 alter bufferpool IBMDEFAULTBP size 88500

db2 alter bufferpool LDAPBP size 3690

Required Fixes

•

The following fixes are required to apply in 6.1 Cluster environment,

•

PK67324 (for Windows is PK67800)

•

WAS DynaCache PK67942

•

WAS DynaCache PK59026 (include PK62850 and prereq PK67942), to

eliminate renounce messages

•

PK70944: to eliminate GroupCache invalidation

•

PK70890: Friendly URL fix

•

The following fix is required to apply in 6.1.0.1 Cluster environment

PK76988: Cluster performance Degradation by large amount of DRS invalidation
messages

Advertising