5. Environmental Requirements

5.1 Temperature

Operating ambient

+10 °C min
+50 °C max

(At full load, with a maximum rate of change of 5 °C/10
minutes, but no more than 10 °C/hr.)

Nonoperating ambient

-40 °C to +70 °C

(Maximum rate of change of 20 °C/hr.)

5.2 Thermal Shock (Shipping)

Nonoperating

-40 °C to +70 °C; 15 °C/min

dT/dt

30 °C/min; 50 cycles;

Duration of exposure to temperature extremes for each half
cycle shall be 30 minutes.

5.3 Humidity

Operating

To 85% relative humidity (noncondensing)

Nonoperating

To 95% relative humidity (noncondensing)
Note: 95% RH is achieved with a dry bulb temperature of
55 °C and a wet bulb temperature of 54 °C.

5.4 Altitude

Operating

To 10,000 ft

Nonoperating

To 50,000 ft

5.5 Mechanical Shock

Nonoperating

50 g, trapezoidal input; velocity change

170 in/s.

Three drops on each of six faces are applied to each sample.