InFocus Laser Platform M-300 User Manual

Page 98

Advertising
background image

8-2

Troubleshooting


Raster engraving appears sharp
on both ends of the engraving
but fuzzy in the middle

•

Dirty laser system

•

Something is loose

•

System needs tuning

•

Worn X-axis belt and/or drive gear


•

Tickle setting too low

•

Faulty laser tube

•

Clean all optics, rails, bearings and belts

•

Check X-axis bearings, drive gear, idler
pulley, belt, and optics

•

Run “Tuning” feature in printer driver
version 4.17 and higher

•

Replace belt and/or drive gear, and run
“Tuning” feature

•

Adjust setting higher and recheck

•

Replace laser tube

Engraving does not appear as
deep as it normally does

•

Graphic, graphic software, graphic
software setup, color palette, monitor
display colors, or driver settings have
changed

•

Out of focus

•

Material or material density has
changed

•

Settings have changed

•

Dirty laser system

•

Laser tube cooling fan filters are dirty

•

Chiller not maintaining
temperature(water cooled versions only)

•

Ambient temperature not within
specifications

•

Laser beam out of alignment with the
optics

•

Air Assist cone misaligned (air assisted
versions only)

•

Faulty laser tube

•

Check to see what has changed. Use
“Software Setup Guide” to properly setup
the graphics software to work correctly
with the laser system. Check driver
settings.

•

Re-focus

•

Check material

•

Check power, speed, PPI, and DPI
settings

•

Clean all optics, rails, bearings and belts

•

Check and/or clean

•

Check, clean, or adjust chiller

•

Adjust ambient temperature to within
specifications

•

Check and/or adjust laser beam
alignment

•

Check and/or adjust cone so that laser
beam is in center

•

Replace laser tube

Engraving is sharp, clear and at
a good depth on one side of the
table and fuzzy and shallow on
the opposite side of the table

•

Out of focus

•

Dirty laser system

•

Material is not level or varying in
thickness


•

Table is not level




•

Laser beam out of alignment with the
optics

•

Air Assist cone misaligned (air assisted

•

Re-focus

•

Clean all optics, rails, bearings and belts

•

Check focus point of material and
different places, adjust height by
shimming material or using more
thickness-consistent material

•

Using the focus tool, focus directly on
the surface of the table in all four
corners. Table should be within +/- .020
inches from one corner to the other.
Adjust if necessary.

•

Check and/or adjust laser beam
alignment

•

Check and/or adjust cone so that laser

Advertising