background image

Table 18. Diagnostic error messages (continued)

Error Code

Meaning

FRU/action

217-XXX-000

Failed BIOS hard disk drive
test
Note: If RAID is configured,
the hard disk drive number
refers to the RAID logical
array.

Hard disk drive 1

217-XXX-001

Failed BIOS hard disk drive
test
Note: If RAID is configured,
the hard disk drive number
refers to the RAID logical
array.

Hard disk drive 2

217-XXX-002

Failed BIOS hard disk drive
test.
Note: If RAID is configured,
the hard disk drive number
refers to the RAID logical
array

Hard disk drive 3

217-XXX-003

Failed BIOS hard disk drive
test
Note: If RAID is configured,
the hard disk drive number
refers to the RAID logical
array.

Hard disk drive 4

217-XXX-004

Failed BIOS hard disk drive
test
Note: If RAID is configured,
the hard disk drive number
refers to the RAID logical
array.

Hard disk drive 5

217-XXX-005

Failed BIOS Fixed Disk test
Note: If RAID is configured,
the hard disk drive number
refers to the RAID logical
array.

Hard disk drive 6

264-XXX-0NN

Failed tape-drive test

1. Tape cartridge, if user executed the read/write tape

drive test (XXX = 256)

2. SCSI or power cable connected to tape drive with SCSI ID

NN.

3. Tape drive with SCSI ID NN (Refer to the Help and

Service Information appendix of the tape drive’s user
guide).

4. System board or SCSI Controller (Run SCSI controller

diagnostic to determine if the SCSI bus is functioning
correctly.)

264-XXX-999

Errors on multiple tape drives See error messages/text in the PC Doctor error log for

detailed information on each individual tape drive error.

301-XXX-000

Failed Keyboard test

Keyboard

405-XXX-000

Failed Ethernet test on
controller on the system
board

1. Verify that Ethernet is not disabled in BIOS

2. System board