TROUBLESHOOTING

NOTE: The following procedures must be performed by a qualified service technician.

Problem

Possible Cause

Solution

“Filt” or “Err” message appears on
the touchpad LED readout

• The filter is dirty and needs to

be cleaned

• The unit is positioned too close

to a wall or other object restrict-
ing air flow and causing the
machine to run at a higher tem-
perature

• The filter is not properly

installed

• The unit has been installed

near a heat source, such as a
coffee machine, ice maker or
cold beverage machine which
expels hot air from its vents,
causing the machine to run at a
high temperature. (Installation
near a heat source should be
avoid)

• Clean and replace filter follow-

ing instructions (Removing and
Cleaning Filter)

• Reposition unit to maximize

ventilation space (see installa-
tion figures)

• Properly install filter see

“Removing and cleaning filter”

• Reposition unit to maximize

ventilation space (see installa-
tion figures)

The machine does not cool, or
cools only partially, but the com-
pressors are running

• The space around the machine

is inadequate for ventilation

• Freezer is in COLD mode

• The condenser fins are clogged

with airborne particles

• Fan motor is not running

• Refrigerant is low

• Allow at least 8” (20cm)

between the machine and any-
thing next to it; keep away from
heat sources

• Return to FROZEN mode

• Remove the side panels. Using

a brush or compressed air
clean the condenser

• Check the fan motor’s electrical

connections and, if discon-
nected, reconnect. If still not
operating, replace the motor

• Locate the leak, eliminate it and

recharge the system

The machine does not cool or
cools only partially, but one or
more of the compressors are not
running

•

Defective Electrical components

•

Loose wire connections

•

One or more of the compressors
are malfunctioning

•

No current is coming to the
“compressor delay” PC board

•

Replace the malfunctioning compo-
nents

•

Check the contacts and correct
those that are incomplete

•

Replace the compressor(s)

•

Check the electrical connections to
the PC board as well as the trans-
former feeding the PC board and
correct