POST Error Code

FRU/Action

1802

PCI/PnP Error! Not Enough I/O Space

Available

1.

Run Setup and verify PCI/ISA
configuration settings.

2.

If necessary, set ISA adapters to Not
available
to allow PCI adapters to
properly configure.

3.

Remove any suspect ISA adapters.

4.

Rerun diagnostics.

5.

PCI Adapter

1803

PCI/PnP Error! Not Enough Memory

Space Available

1.

Run Setup and verify PCI/ISA
configuration settings.

2.

If necessary, set ISA adapters to Not
available
to allow PCI adapters to
properly configure.

3.

Remove any suspect ISA adapters.

4.

Rerun diagnostics.

5.

PCI Adapter

1804

PCI/PnP Error! Not Enough Real

Memory Space Available

1.

Run Setup and verify PCI/ISA
configuration settings.

2.

If necessary, set ISA adapters to Not
available
to allow PCI adapters to
properly configure.

3.

Remove any suspect ISA adapters.

4.

Rerun diagnostics.

5.

PCI Adapter

1805

PCI/PnP Error! Adapter ROM

Checksum Error

1.

Run Setup and verify PCI/ISA
configuration settings.

2.

If necessary, set ISA adapters to Not
available
to allow PCI adapters to
properly configure.

3.

Remove any suspect ISA adapters.

4.

Rerun diagnostics.

5.

PCI Adapter

180X, 188X
PCI configuration or resource error

1.

Run Setup and verify PCI/ISA
configuration settings.

2.

If necessary, set ISA adapters to Not
available
to allow PCI adapters to
properly configure.

3.

Remove any suspect ISA adapters.

4.

Rerun diagnostics.

5.

PCI Adapter

1962
No operating system found

1.

Press F1 to repeat boot sequence.

209X

1.

Diskette Drive

2.

Diskette Cable

20XX
Not listed above

1.

BSC Adapter

66