Trouble shooting – Ingersoll-Rand PD10P-X User Manual

Page 7

Advertising
background image

PD10P-X

Page 7 of 8

168

111

TORQUE REQUIREMENTS

NOTE: DO NOT OVERTIGHTEN FASTENERS.

ALL FASTENERS ARE METRIC.

Torque (105 and 134) screw to 35 - 40 in. lbs (4.0 - 4.5 Nm).

LUBRICATION / SEALANTS

Apply anti-seize compound to threads at assembly.

Apply Lubriplate FML-2 grease to “O" rings, “U" Cups & mating parts.

139

138

134

135

133

174

121

118

173

169

172

171

170

167

121

174

118

166

132

141

140

200

233

176

PILOT VALVE

PART GROUP

MAJOR

VALVE

A replacement Major Valve Service Assembly is available separately, which includes the following:

637395-1 for models PD10P-X: 105 (4), 107 (2), 111, 132, 135, 136, 137, 138, 139, 140, 141, 166,

176 (2), 200, 233 and 236 (4)

637395-2 for models PE10P-X: 76, 105 (4), 107 (2), 111, 132, 135, 136, 137, 138, 139, 140, 141, 166,

176 (2), 200, 233 and 236 (4)

Figure 3

101

181

103

201

173

136

107

105

236

137

107

Insert screwdriver here to remove (233) adapter plate.

Notch

PARTS LIST / PX10P-X AIR SECTION

TROUBLE SHOOTING

Product discharged from exhaust outlet.

Check for diaphragm rupture.
Check tightness of (6) diaphragm washer.

Air bubbles in product discharge.

Check connections of suction plumbing.
Check O” rings between intake manifold and inlet side
fl uid caps.
Check tightness of (6) diaphragm washer.

Motor blows air or stalls.

Check (176) check valve for damage or wear.
Check for restrictions in valve / exhaust.

y

y

y

y

y

y

y

Low output volume, erratic fl ow, or no fl ow.

Check air supply.
Check for plugged outlet hose.
Check for kinked (restrictive) outlet material hose.
Check for kinked (restrictive) or collapsed inlet material
hose.
Check for pump cavitation − suction pipe should be sized
at least as large as the inlet thread diameter of the pump
for proper fl ow if high viscosity fl uids are being pumped.
Suction hose must be a non-collapsing type, capable of
pulling a high vacuum.
Check all joints on the inlet manifolds and suction con-
nections. These must be air tight.
Inspect the pump for solid objects lodged in the dia-
phragm chamber or the seat area.

y

y

y

y

y

y

y

Advertising