Label gap sensor calibration – Intermec EASYCODER PD4 User Manual

Page 73

Advertising
background image

Intermec EasyCoder PD4—User’s Guide

63

Chapter 9—Adjustments

Label Gap Sensor Calibration

The label gap sensor will need to be calibrated and the media feed

adjusted at the following occasions:
• After media load when the printer is used for the first time.
• After loading media that differs from the previously loaded in regard

of type (gaps, black marks, or continuous), size and location of gaps or

black marks, or transparency of the liner.

• When the printer starts feeding out labels or similar in an unexpected

way or when the print image becomes positioned in the wrong place.

The calibration is performed in the Autosensing Mode. Do like this:
1

Switch off the printer.

2

Switch on the printer while holding the Pause key.

3

If the printer is fitted with a display, it will show the following mes-

sage:

4

The printer will feed out some labels or similar while checking the

characteristics of the media and autoadjust the sensitivity and the feed

parameters.

5

Provided the printer has a display, one of the following messages is

briefly displayed depending on type of media, when the calibration is

completed:

6

The printer switches automatically to the Direct Mode.

To break the Autosensing Mode before it is finished and enter the

Direct Mode, press the Cancel key.

Advertising