Installation and Lubrication

Size air supply line to ensure tool's maximum operating pressure (PMAX) at tool inlet.
Drain condensate from valve(s) at low point(s) of piping, air filter and compressor tank daily.
Install a properly sized Safety Air Fuse upstream of hose and use an anti-whip device
across any hose coupling without internal shut-off, to prevent hose whipping if a hose fails
or coupling disconnects. See drawing 04581666 and table on page 2. Maintenance
frequency is shown in circular arrow and defined as h=hours, d=days, and m=months.
Items identified as:

Parts and Maintenance

When the life of the tool has expired, it is recommended that the tool be disassembled,
degreased and parts be separated by material so that they can be recycled.

The original language of this manual is English.

Tool repair and maintenance should only be carried out by an authorized Service Center.

Refer all communications to the nearest Ingersoll Rand Office or Distributor.

Model

Impacting

Sound Level dB (A)

(ISO15744)

Free Speed

Sound Level dB (A)

(CAGI/ANSI S12.41)

Vibration

Level

(ISO8662)

† Pressure (L

p

)

‡ Power (L

w

)

Pressure

Power m/s²

2135Ti

96.6

107.6

101.2

114.2

5.3

2135Ti-2

96.6

107.6

101.2

114.2

5.3

2135QTi

94.2

105.2

86.0

96.0

5.3

2135QTi-2

94.2

105.2

86.0

96.0

5.3

2135QPTi

94.2

105.2

86.0

96.0

5.3

2135PTi

96.6

107.6

101.2

114.2

5.3

† K

pA

= 3dB measurement uncertanity

‡ K

wA

= 3dB measurement uncertanity

1. Air filter

7. Coupling

2. Regulator

8. Safety Air Fuse

3. Lubricator 9. Oil
4. Emergency shut-off valve

10. Grease - during assembly

5. Hose diameter

11. Grease - through fitting

6. Thread size