Indesit FIE 76 KC.A GB/1 User Manual

Page 3

Advertising
background image

3

GB

DATA PLATE

Dimensions

width cm 43.5
height cm 32
depth cm 40

Volume

lt. 56

Electrical
connections

voltage: 230-240V ~ 50Hz
maximum power absorbed 2800-
3000W

ENERGY LABEL

Directive 2002/40/EC on the label
of electric ovens.
Norm EN 50304
Energy consumption for Natural
convection – heating mode:
Traditional mode
Declared energy consumption for
Forced convection Class – heating
mode: Baking

This appliance conforms to the
following European Economic
Community directives:
-2006/95/EEC of 12/12/06 (Low
Voltage) and subsequent
amendments;
- 89/336/EEC of 03/05/89
(Electromagnetic Compatibility) and
subsequent amendments;
- 93/68/EEC of 22/07/93 and
subsequent amendments.
- 2002/96/EC

GREEN &
YELLOW

BROWN

BLUE

13 amp fuse

CROSS-BAR
CORD GRIP

How to connect an alternative plug

The wires in this mains

lead are coloured in

accordance with the

following code:

BLUE“NEUTRAL” (N)

B R O W N

“LIVE” (L)

GREEN AND YELLOW

“EARTH” (E)

Disposing of the appliance

When disposing of the appliance please remove the

plug by cutting the mains cable as close as

possible to the plug body and dispose of it as

described above.

! The plug and socket must be easily accessible.

if the cooker is connected directly to the mains, an

omnipolar circuit-breaker with a minimum opening of

3 mm between the contacts, suitable for the load

indicated and complying with current directives,

must be installed between the appliance and the

mains (the earthing wire must not be interrupted by

the circuit-breaker). The power supply cable must be

positioned so that it does not exceed room

temperature by 50°C at any point of its length.

Before making the connection check that:

• the circuit breakers or fuses of the home system

can support appliance load (see data plate);

• the power supply system has an efficient earthing

connection which complies with the provisions of

current regulations and the law;

• there is easy access to the socket or the

omnipolar circuit-breaker once the cooker has

been installed.

! do not use reducers, adapters or shunts as these

could cause heating or burning.

Connection n° 2

Disposing of the plug.
! THIS APPLIANCE MUST BE EARTHED.

Ensure that before disposing of the plug itself, you

make the pins unusable so that it cannot be

accidentally inserted into a socket. Instructions for

connecting cable to an alternative plug:

! the wires in the mains lead are coloured in

accordance with the following code:

Green & Yellow

-Earth

Blue

-Neutral

Brown

-Live

If the colours of the wires in the mains lead do not

correspond with the coloured markings identifying

the terminals in your plug, proceed as follows.

Connect Green & Yellow wire to terminal marked “E”

or 6 or coloured Green or Green & Yellow.

Connect Brown wire to terminal marked “L” or

coloured Red. Connect Blue wire to terminal marked

“N” or coloured Black. If a 13 amp plug (BS 1363) is

used it must be fitted with a 13 amp fuse.

A 15 amp plug must be protected by a 15 amp

fuse, either in the plug or adaptor or at the

distribution board.If you are in any doubt about the

electrical supply to your machine, consult a qualified

electrician before use.