Start-Up Procedure

Page 15

Bin Control Operation

The bin control is used to shut the machine off when the bin fills with ice. The bin control must be checked upon
installation or initial start-up and when performing maintenance.

There is one bin switch for each evaporator. The actuator arm of the bin switch comes in contact with the splash
curtain. When the bin is full of ice, the splash curtain is held open when ice drops off of the evaporator. This releases
the pressure of the bin switch actuator arm allowing the switch to open.

Single evaporator machines: (Including the CCM1530) If the bin switch opens during freeze or the first part of
harvest, relay 2 bypasses the bin switch and the machine will continue running. If the bin switch is opened during
harvest when the cam switch is lifted onto the high part of the cam, the machine will shut off. When the bin switch
closes again, the machine will restart.

Dual evaporator machines: If either bin switch opens during the freeze cycle, the machine will shut off. Relay 1 and
relay 2 will bypass the bin switches during defrost. If either bin switch is open when the machine returns to the freeze
cycle, the machine will shut off.

Evaporator

Splash Curtain

Bin Switch
Adjustment
Nuts

Undercounter machines: A thermostatic bin control is used on the undercounter
models. The bin thermostat is located in the control box with a capillary tube,
which is in a brass thermo-well mounted to the water trough. When ice comes in
contact with the capillary tube thermo-well, the bin thermostat opens and the
machine will shut off.

Bin Control Adjustment

All Models (Except Undercounter Models): Check the bin switch for proper
adjustment by swinging the bottom of the curtain away from the evaporator.
Slowly bring the curtain towards the evaporator. The switch should close when
the bottom edge of the curtain is even with the outer edge of the water trough.
Adjust the switch by loosening the nuts that hold the switch in place. Move the
switch to the proper position and retighten the nuts. Recheck the adjustment.

Undercounter Models
Turn the machine to the ICE or WASH position. Hold ice against the brass
thermal-well mounted to the water trough making sure the ice is in contact with at
least 6 inches (15 cm) of the thermal-well. The machine should shut off in

approximately 1 minute. Remove
the ice. The machine should
restart in approximately 3
minutes. If a major adjustment is
required, turn the adjustment
screw counterclockwise (warmer)
until it stops then turn the
adjustment screw clockwise
(colder) 1/8 of a turn. This
should put the control close to
the proper adjustment, recheck
and make a minor adjustment if
needed. If a minor adjustment is
required, turn the adjustment
screw clockwise (colder) or
counterclockwise (warmer).

The bin switch
contacts must be
closed when the
bottom edge of the
curtain is flush with
the edge of the
water trough

Thermal -well

Thermostatic
Bin Control