Installation, Where to install the tumble dryer, Ventilation – Indesit IDVA 735 User Manual

Page 2

Advertising
background image

2

EN

Installation

Where to install the tumble dryer

• Install the dryer far from gas

ranges, stoves, radiators or

hobs, as flames may damage it.

If the dryer is installed below a

worktop, ensure there are 10

mm between the upper panel of

the dryer and any objects above

it, and 15 mm between the sides

of the machine and the walls or

furniture units adjacent to it. This

ensures adequate air circulation. Make sure the air inlets on

the rear panel are not blocked or obstructed.

You should also make sure that the room in which the

tumble dryer is installed is not damp, and that it is

adequately ventilated.

Ventilation

This appliance gently dries laundry by taking in cold, clean and

relatively dry air, heating it and passing it through the fabric.

To facilitate the drying process, damp air is expelled at the

rear, through a ventilation hose. It is important that the room

in which the tumble dryer is used is adequately ventilated, in

order to avoid the recirculation of waste gases expelled by

other appliances.

Mobile ventilation system
When using the tumble dryer with the mobile ventilation

system, a ventilation hose must be connected. The hose

should be securely fastened to the ventilation hole at the rear of

the appliance (see “Description of the tumble dryer”). We

recommend the hose is connected to an outlet near the tumble

dryer, if possible. If it cannot be installed in a permanent spot,

the tumble dryer will still function perfectly well if the ventilation

hose is passed through a partially-opened window.

 Make sure you do not point the ventilation hose towards the

air inlet, which is located on the rear of the appliance.

 The ventilation hose should not exceed a maximum length of

2.4 metres; it should also be shaken frequently to remove any

fluff, dust or water deposits inside it. Make sure you do not

crush the hose.

Fixed ventilation system
We recommend the ventilation hose is connected to a

ventilation system for windows or doors, available from the

retailer which originally sold you the appliance or from your

local spare parts stockist.

Wall ventilation hole

1. Leave an opening in the wall to

the left of the tumble dryer

installation site.

2. Make the hose as short and

straight as possible, in order to

prevent any dampness from

condensing and leaking back into

the appliance.

3. The hole in the wall must also

be straight and pointing

downwards, so that the flow of air coming out is not

impeded.

Areas A and B should be checked frequently, to prevent the

accumulation of fluff or debris, particularly if the tumble dryer

is used very often. The hose adaptor must be fitted

correctly, in order to prevent damp air from coming back

into the room.

Window ventilation hole

1. Theoretically, when the

tumble dryer is operating with a

full load, the ventilation hole

should be directly behind the

fan.

2. It is therefore important that

the hose is as short as

possible.

 Make sure you do not push

the tumble dryer too far

backwards, as this could lead to the ventilation hose being

crushed, bent or even disconnected.

 There should be no cuts, bottlenecks or “U”-shaped bends

in the hose, as these could impede ventilation or trap

condensation.

Ventilation through an open window

The end of the hose must be

facing downwards, in order to

prevent the hot, damp air from

forming condensation in the

room or the tumble dryer.

 Make sure that the tumble dryer is adequately ventilated,

and that the end of the ventilation hose is not pointing

towards the air inlet pipe on the rear of the appliance.

 The ventilation hose must always be fitted to ensure

correct tumble dryer operation.

 Make sure that the ventilation hose and the air inlet pipes

are not obstructed or blocked.

 Do not let the tumble dryer recirculate foul air.

 Improper use of the tumble dryer may result in fire

hazards.

 The air emitted by the tumble dryer should not be expelled

in the same duct as used for the fumes produced by

different appliances which burn gas or other fuels.

B

A

1

0

m

m

15 mm

15 mm

15 mm

15 mm