Shipping dimensions, Environmental requirements and specifications, Temperature and humidity – IBM System Storage Subsystem DS5020 User Manual

Page 50

Advertising
background image

the storage subsystem in different configurations. Table 3 lists the weight of each
component.

Table 2. DS5020 weights

Unit

Weight

Maximum

1

Empty

2

Shipping

DS5020

40 kg (88 lb)

16.4 kg (36.1 lb)

52.2 kg (115.0 lb)

1

Chassis with all CRUs and 16 drives.

2

Chassis without CRUs and drives but with front cage frame and midplane.

Table 3. DS5020 component weights

Unit

Weight

Drive

0.75 kg (1.65 lb)

Power supply and fan unit

3.60 kg (7.95 lb)

Controller (including cache battery backup
unit)

2.8 kg (6.1 lb)

Battery unit

0.9 kg (2 lb)

Shipping dimensions

Table 4 lists shipping carton dimensions. The height shown includes the height of
the pallet.

Table 4. DS5020 shipping carton dimensions

Height

Width

Depth

45.7 cm (18.0 in.)

62.6 cm (24.5 in.)

80.7 cm (31.75 in.)

Environmental requirements and specifications

This section describes the environmental requirements and specifications for the
DS5020 storage subsystem, including temperature and humidity, altitude, airflow
and heat dissipation, shock and vibration requirements, and acoustic noise levels.

Temperature and humidity

Table 5 on page 21 lists the acceptable temperature and humidity ranges for the
DS5020 storage subsystem when in storage or in transit. Table 6 on page 21 lists
temperature and humidity ranges for the storage subsystem in typical Information
Technology (IT) or office environments.

Note: Substantial deviations from the suggested operating range, in either

direction, if sustained for extended periods of time, will expose the unit to
greater risk of failure from external causes.

Important: The operating environment air temperature must be 22° C (72° F) or

lower.