29

91704

YES

4. BEVERAGE SYSTEM PROBLEM

NO

IS

ONE OR MORE

FAUCETS

INOPERATIVE?

1. CHECK WIRING CONNECTIONS TO IN-

OPERATIVE FAUCETS.

2. REPLACE INOPERATIVE FAUCETS.
3. CHECK WIRING CONNECTIONS FROM

24V. TRANSFORMER.

4. CHECK 24V. TRANSFORMER.

IS

BEVERAGE

COLD?

IS

BEVERAGE

PROPERLY

CARBONATED?

IS

BEVERAGE

TOO SWEET?

IS

BEVERAGE

TOO WATERY?

DONE

1. CHECK REMOTE COOLING

SYSTEM. (-B MODELS)

2. CHECK FOR ICE ON COLD

PLATE. (-BC MODELS)

3. CHECK CO

2

PRESSURE.

4. CHECK CARBONATOR.

1. CHECK WATER SUPPLY PRESSURE.
2. CHECK SUPPLY FILTER.
3. CHECK CARBONATOR.
4. CHECK FAUCET BRIX.

1. CHECK IF SYRUP TANK IS EMPTY.
2. CHECK CO

2

PRESSURE.

3. CHECK FAUCET BRIX.

NO

NO

NO

NO

YES

YES

YES

YES