Figure 4 and, 1 meters). refer to table 3 – IPSO 120 User Manual

Page 16

Advertising
background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Tumblers – 120 and 170

4-08-45

15

Figure 4

TMB2019N

1

NOTE: Where the exhaust duct pierces a
combustible wall or ceiling, the opening
MUST be sized per local codes.

2

Outlet Duct Diameter

3

45° Typical

L

K

J

I

H

G

F

E

D

C

B

A

3

1

2

ONE MANIFOLD ASSEMBLY

Duct

Station

120 Pound

170 Pound

10 in. (254 mm) Duct

12 in. (305 mm) Duct

A

10 in. (254 mm)

12 in. (305 mm)

B

15 in. (381 mm)

17 in. (432 mm)

C

18 in. (457 mm)

21 in. (533 mm)

D

21 in. (533 mm)

24 in. (610 mm)

E

24 in. (610 mm)

27 in. (686 mm)

F

26 in. (660 mm)

30 in. (762 mm)

G

28 in. (711 mm)

32 in. (813 mm)

H

30 in. (762 mm)

34 in. (864 mm)

I

32 in. (813 mm)

36 in. (914 mm)

J

33 in. (838 mm)

38 in. (965 mm)

K

35 in. (889 mm)

40 in. (1016 mm)

L

36 in. (914 mm)

42 in. (1067 mm)

Table 3

Advertising
This manual is related to the following products:

170