NOTE: THRESHOLD: The Threshold is always OFF when the door is closed.

NOTE: PATTERN WIDTH OR DEPTH: When pattern width or depth is changed, a setup of the new

pattern size will automatically be triggered once a value key has been pressed.

















Pattern Width
Door Open or

Closed


1: Wide (closed door)
2 : Middle (open door)
3 : Asymmetric Left Narrow
4 : Asymmetric Right Narrow
5 : Narrow Left
6 : Narrow Right
7 : Asymmetric Left Wide
8 : Asymmetric Right Wide
9 : Center Narrow

See Note: Pattern Width or Depth

Pattern Depth

1: Deep – Threshold ON
2 : Medium – Threshold ON (open)
3 : Limited – Threshold ON
4 : Deep – Threshold OFF
5 : Medium – Threshold OFF (closed)
6 : Limited – Threshold OFF

See Note: Threshold
See Note: Pattern Width or Depth

Sensitivity

Door Open-Closed

0 (min)

9 (max) (default 7 for

door open, default 6 for door
closed)

Immunity

1: Normal
2 : Rain Mode
3 : Snow Mode

Automatic Learn

Time


0: 30 seconds
1: 1 minute
2: 2 minutes
3: 3 minutes
4: 5 minutes
5: 7 minutes
6: 10 minutes
7: 15 minutes
8: 10 seconds
9: Infinity – no learn