Page 5

Physical and Environmental Characteristics

Physical Characteristics

Description

Dimensions (H x W x D)

188mm x 66mm x 42mm

Weight (with battery)

0.3Kg

Environmental Characteristics

Description

Temperature operating

0 to + 50ºC

Non-Operating

-20 to + 60ºC

Humidity (operating)

< 80% R.H.

Altitude Operating

2,000 m (6560 ft.)

Non-Operating

12,300 m (40354 ft.)

Vibration & shock Operating

MIL-T-28800E (5 ~ 55Hz, 3g maximum)

Conductor Size

12mm (0.5”)

Indoor Use

Indoor Use



Certifications and Compliances

Safety

Designed to IEC 1010-1, UL3111-1 and CSA specifications

Input rating

IEC 1010 600V CAT. III

Over voltage category

CAT III: Distribution level mains, fixed installation.

CAT II: Local level mains, appliances, portable equipment.

CAT I: Signal level, special equipment or parts of equipment,
telecommunication, electronics.

Pollution Degree 2

Do not operate in environments where conductive pollutants may
be present.

EC Declaration of Conformity

Meets the intent of Directive 89/336/EEC for Electromagnetic
Compatibility and Low Voltage Directive 73/23/EEC for
Product Safety. Compliance was demonstrated to the following
specifications as listed in the official Journal of the European
Communities:

EN 55011 Class A: Radiated and Conducted
Emissions.
EN 50082-1 Immunity: IEC 801-2 Electrostatic Discharge
IEC 801-3 RF Radiated
EN 61010-1 Safety requirements for electrical equipment for
measurement, control, and laboratory use.


Form number TM61095

Rev 2 September 2002