Warning – IPSO CHM2097N User Manual

Page 25

Advertising
background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Washer-Extractors

24

5-08-51

Electrical Installation Requirements - Model IWF033 (2-speed)

Only trained personnel should perform this

procedure. Use caution while servicing

machines with covers removed and power

applied.

W700

WARNING

Boiler Fed/Steam Heat

Electric Heat

Co
de

Vo
lta

g

e

Cy
cl

e

Phase

Wir
e

Full Lo

ad

Amp

s

Recommended

Circu

it Br
eak
er

(U

S-mar

ket
)

AW
G

/m

m

2

kW S

ta

nda

rd

Heat

ing Ele

m

ent
s

Full Lo

ad

Amp

s

Recommended

Circu

it Br
eak
er

(U

S-mar

ket
)

AW
G

/m

m

2

US NON-US

US

NON-US

N 440-480

50/60

3

3+PE

4

10

10

14/2.5

6x3 kW

30

40

40

8/10.0

P

380-415

50/60

3

3+N+PE

12

15

16

14/2.5

38

50

50

8/10.0

Q 200-240

50/60

3

3+PE

12

15

16

14/2.5

57

70

70

4/25.0

X 200-240

50/60

1/3

2/3+PE

12

15

16

14/2.5

N/A

N/A

N/A

N/A

Alternative Electric Heat Options

N 440-480

50/60

3

3+PE

3x3 kW

+

3x2 kW

26

30

30

10/6.0

P

380-415

50/60

3

3+N+PE

34

40

40

8/10.0

Q 200-240

50/60

3

3+PE

50

60

60

6/16.0

X 200-240

50/60

1/3

2/3+PE

N/A

N/A

N/A

N/A

N 440-480

50/60

3

3+PE

3x3 kW

+

3x4 kW

34

40

40

8/10.0

P

380-415

50/60

3

3+N+PE

53

60

60

6/16.0

Q 200-240

50/60

3

3+PE

N/A

N/A

N/A

N/A

X 200-240

50/60

1/3

2/3+PE

N/A

N/A

N/A

N/A

N 440-480

50/60

3

3+PE

6x2 kW

21

30

30

10/6.0

P

380-415

50/60

3

3+N+PE

30

40

40

8/10.0

Q 200-240

50/60

3

3+PE

42

50

50

8/10.0

X 200-240

50/60

1/3

2/3+PE

N/A

N/A

N/A

N/A

N 440-480

50/60

3

3+PE

6x4 kW

39

50

50

8/10.0

P

380-415

50/60

3

3+N+PE

47

60

60

6/16.0

Q 200-240

50/60

3

3+PE

N/A

N/A

N/A

N/A

X 200-240

50/60

1/3

2/3+PE

N/A

N/A

N/A

N/A

Table 5

Advertising