Ice-O-Matic ICE0805 User Manual

Ice-o-matic, Cube i ce m ak er, E. d. f. b

Advertising
background image

11100 E. 45th Avenue
Denver, CO 80239

Phone:

303. 371.3737

Fax:

303. 371.6296

www.iceomatic.com

Rev:

A-05/08

Ice-O-Matic

®

Part:

1010

IC

E0

80

6/0

80

5

C

ube I
ce M
ak

er

Air Cooled

Please note: air-cooled units require 6 (152 mm) clearance for

air intake and exhaust

Ice maker potable water in, 3/8" FPT.

A.

Ice maker water out, 3/4" FPT.

B.

Hole for electrical connections, 7/8".

C.

Electrical connection junction box.

D.

Air In–

Rear

Standard Side

Discharge

30"

(762mm)

26" (508 mm)

24"

(610mm)

5" (127mm)

Bin Hanger

5" (127mm)

Bin Hanger

.7" (17.8 mm)

2.6"(66.8 mm)

17.7"

(449.6 mm)

20.5"

(520.7 mm)

22.2"

(564 mm)

B.

C.

D.

A.

.62" (16mm)

Air Cooled

Water Cooled/Remote

Ice maker potable water in, 3/8" FPT.

A.

Ice maker water out, 3/4" FPT.

B.

Hole for electrical connections, 7/8".

C.

Condenser water in, 3/8" FPT.

D.

Condenser water out, 1/2" FPT.

E.

Liquid line, 3/8" male quick connect

F.

coupling for precharged line set
(remote only).
Discharge line, 1/2" male quick connect

G.

coupling for precharged line set
(remote only).
Hole for remote electrical connections,

H.

7/8" (remote only).

22.2"

(564 mm)

5" (127mm)

Bin Hanger

5" (127mm)

Bin Hanger

.7"

(17.8 mm)

2.6"

(66.8 mm)

.62" (16mm)

17.7"

(449.6 mm)

20.5"

(520.7 mm)

22.2"

(564 mm)

E.

D.

F.

B.

C.

A.

3.5" (88.9 mm)

G.

H.

3.0" (76.2 mm)

I.

Water Cooled & Remote

Operating Requirements

Minimum

Maximum

60 Hz

50Hz

Ambient Temp. Range Air

50˚F (10˚C)

100˚F (38˚C)

110˚F (43˚C)

Water Temp.

40˚F (4.4˚C)

100˚F (38˚C)

110˚F (43˚C)

Water Pressure

20 PSIG (1.4 BAR)

60 PSIG (4.1 BAR)

Dimensions

All Models

W x D x H (inches)

30 x 24 x 26

W x D x H (mm)

762 x 610 x 508

Specifications

Model Number Cond. Unit

Ice Production

per 24hrs

Water Usage

gallons per 100 lbs of Ice

90°F air/70°F water

kWH Used
per 100 lbs

of ice @

90°F air/

70°F water

Voltage

Characteristics

Min.

Circuit

Ampacity

Fuse

Size

Approx.

BTUs

per hour

70°F air/

50°F water

lbs (kg)

90°F air/

70°F water

lbs (kg)

Potable

Condenser

ICE0806A

Air

957 (435)

698 (317)

21.8

-

5.8

208-230/60/1

13.0

20

14,464

ICE0806R

Remote*

968 (440)

826 (375)

20.0

-

5.3

208-230/60/1

12.3

20

16,371

ICE0806W

Water

955 (434)

855 (389)

24.9

132

4.0

208-230/60/1

9.8

20

14,816

ICE0805A

Air

918 ( 417)

641 (291)

21.0

-

6.0

230/50/1

11.7

16

13,576

ICE0805R

Remote*

962 (437)

790 (359)

20.3

-

4.9

230/50/1

13.1

16

15,031

ICE0805W

Water

947 (430)

853 (388)

25.7

124

4.0

230/50/1

9.2

16

14,810

*Requires Remote VRC 2061 Condenser and precharged line set

NOTES:
Number of Wires:

3 (including ground)

Approx. Shipping Weight lbs (kg):

ICE0806A 220 (100) • ICE0806R 220 (100) • ICE0806W 210 (96) ) • ICE0805A 220 (100) • ICE0805R 220 (100) • ICE0805W 210 (96)

Refrigerant Type:

R404A

IC

E0

80

6/0

80

5

C

ube I
ce M
ak

er

ICE_Cubers.indd 15

5/8/08 11:21:47 AM

Advertising