Safety instructions, Description and specifications, Engineering data – ITT IRRI-GATOR GT30 User Manual

Page 2: Piping

Advertising
background image

2

DANGER

WARNING

CAUTION

WARNING

Hazardous Fluids
can cause fire,
burns or death.

Safety Instructions

TO AVOID SERIOUS OR FATAL PERSONAL
INJURY OR MAJOR PROPERTY DAMAGE, READ AND
FOLLOW ALL SAFETY INSTRUCTIONS IN MANUAL AND
ON PUMP.

This is a SAFETY ALERT SYMBOL. When
you see this symbol on the pump or in the
manual, look for one of the following signal
words and be alert to the potential for
personal injury or property damage.

Warns of hazards that WILL cause serious
personal injury, death or major property
damage.

Warns of hazards that CAN cause serious
personal injury, death or major property
damage.

Warns of hazards that CAN cause personal

injury or property damage.

NOTICE: Indicates special instructions which are very

important and must be followed.

THIS MANUAL IS INTENDED TO ASSIST IN THE
INSTALLATION AND OPERATION OF THIS UNIT
AND MUST BE KEPT WITH THE PUMP.

THOROUGHLY REVIEW ALL INSTRUCTIONS AND
WARNINGS PRIOR TO PERFORMING ANY WORK
ON THIS PUMP.

MAINTAIN ALL SAFETY DECALS.

NOTICE:INSPECT UNIT FOR DAMAGE AND

REPORT ALL DAMAGE TO THE CARRIER
OR DEALER IMMEDIATELY. DO NOT USE
PUMP IF DAMAGE IS SUSPECTED.

UNITS NOT DESIGNED FOR USE
WITH HAZARDOUS LIQUIDS OR
FLAMMABLE GASES.

Description and Specifications

The Model GT embraces a line of end suction, single

stage, self-priming centrifugal pumps for lawn sprinkling,
HVAC systems, and general water transfer.

Casing is cast iron construction with tapped openings

provided for vacuum gauge and casing drain.

Impellers are enclosed design, glass filled Noryl

TM

,

threaded directly on motor shaft.

Standard motors are NEMA standard, 3500 RPM, open

drip proof enclosure.

Engineering Data

Model

HP

Ph/Hz

Suction

Discharge

Wt. lbs.

GT07

3

4

48

GT10

1

52

GT15

1

1

2

1/60

60

GT20

2

65

GT30

3

76

GT073

3

4

49

GT103

1

52

GT153

1

1

2

3/60

55

GT203

2

69

GT303

3

71

Maximum Liquid Temperature: 160ºF (71ºC)

Maximum Starts per Hour: 20 – evenly distributed

Piping

Pump MUST be installed horizontally on a solid flat

surface, with discharge on top.

Allow adequate space for servicing and ventilation.

Protect the unit from weather and water damage due to
rain or flooding or freezing temperatures.

Piping should be no smaller than the suction and

discharge connections and kept short as possible,
avoiding unnecessary fittings to minimize friction losses.

All piping MUST be independently supported and

MUST NOT place any piping loads on the pump.

NOTICE: DO NOT FORCE PIPING INTO PLACE

AT PUMP SUCTION AND DISCHARGE
CONNECTIONS.

All pipe joints MUST be airtight.

The use of Teflon

TM

tape, or equivalent, is recommended

for ALL pipe joints.

SUCTION

Total suction lift, including elevation and pipe friction

loss, should not exceed 25 feet of head.

Install an airtight union in the suction line close to the

pump. See Figure 1.

Installation of a foot valve at liquid source is

recommended.

NOTICE: FOR INSTALLATIONS WITH LONG

SUCTION PIPING, BOTH A FOOT VALVE
AND A CHECK VALVE ARE
RECOMMENDED.

To avoid air pockets, no part of the piping should be

above the pump suction connection and piping should
slope upward from liquid source.

For installations with long suction piping, fill the suction

pipe with water before connecting to pump.

1

1

2

” NPT

1

1

2

” NPT

Advertising