SECTION 5 ADJUSTMENT PROCEDURES

5-1 PREPARATION

When adjusting IC-F60/F61, the optional CS-F50 ADJ

ADJUSTMENT SOFTWARE

(Rev. 1.0 or later), *OPC-966

JIG CABLE

(modified

OPC-966

CLONING CABLE

) are required.

REQUIRED TEST EQUIPMENT

SYSTEM REQUIREMENTS

• Microsoft

®

Windows

®

95 or Windows

®

98

• RS-232C serial port

ADJUSTMENT SOFTWARE INSTALLATION

q Boot up Windows.

- Quit all applications when Windows is running.

w Insert the cloning software CD-ROM into the appropriate

CD-ROM drive.

e Select ‘Run’ from the [Start] menu.
r Type the setup program name using the full path name,

then push [Enter] key.

(For example; D:\Setup.exe)

t Follow the prompts.
y Program group ‘CS-F50 ADJ’ appears in the ‘Programs’

folder of the [Start] menu.

BEFORE STARTING SOFTWARE ADJUSTMENT

Program the adjustment frequencies, listed in page 5-2, into
the transceiver using with the CS-F50 before starting the
software adjustment. Otherwise, the transceiver can not
start software adjustment.

CAUTION!:

BACK UP the originally programed memory
data in the transceiver before progaming the
adjustment frequencies.
When program the adjustment frequencies
into the transceiver, the transceiver’s memory
data will be overwritten and lose original mem-
ory data at the same time.

STARTING SOFTWARE ADJUSTMENT

q Connect IC-F60/F61 and PC with *OPC-966

JIG CABLE

.

w Turn the transceiver power ON.
e Boot up Windows, and click the program group ‘CS-F50

ADJ’ in the ‘Programs’ folder of the [Start] menu, then
CS-F50 ADJ’s

window appears.

r Click ‘Connect’ on the CS-F50’s window, then appears

IC-F60/F61’s up-to-date condition.

t Set or modify adjustment data as desired.

Microsoft and Windows are registered trademarks of
Microsoft Corporation in the U.S.A. and other countries.

EQUIPMENT

DC power supply

FM deviation meter

Frequency counter

Digital multimeter

RF power meter
(terminated type)

GRADE AND RANGE

Output voltage

: 7.5 V DC

Current capacity

: 5 A or more

Frequency range

: DC–600 MHz

Measuring range

: 0 to ±10 kHz

Frequency range

: 0.1–600 MHz

Frequency accuracy : ±1 ppm or better
Sensitivity

: 100 mV or better

Input impedance

: 10 M

Ω/V DC or better

Measuring range

: 1–10 W

Frequency range

: 300–600 MHz

Impedance

: 50

SWR

: Less than 1.2 : 1

EQUIPMENT

Audio generator

Attenuator

Standard signal
generator (SSG)

DC voltmeter

Oscilloscope

AC millivoltmeter

GRADE AND RANGE

Frequency range

: 300–3000 Hz

Output level

: 1–500 mV

Power attenuation

: 40 or 50 dB

Capacity

: 10 W or more

Frequency range

: 300–600 MHz

Output level

: 0.1 µV–32 mV

(–127 to –17 dBm)

Input impedance

: 50 k

Ω/V DC or better

Frequency range

: DC–20 MHz

Measuring range

: 0.01–20 V

Measuring range

: 10 mV–10 V