Software adjustments (rx), Software adjustments (receiving) – Icom IC-F51 User Manual

Page 18

Advertising
background image

MAIN

Front

panel

Minimum distortion

level

Set “SQL level” to
close squelch.

Then set “SQL level”
at the point where
the audio signals
just appears.

5 -

5

*The output level of the standard signal generator (SSG) is indicated as the SSG’s open circuit.

SOFTWARE ADJUSTMENTS (RECEIVING)

• Select an operation using [

↑] / [↓] keys, then set specified value using [←] / [→] keys on the connected computer keyboard.

• Need to adjust “S-METER ADJUSTMENT” after “RX SENSITIVITY ADJUSTMENT” is adjusted.

Otherwise, “S-METER ADJUSTMENT” will not be adjusted properly.

1

1

2

1

• Operating CH

: CH11

• Connect a standard signal generator to

the antenna connector and set as:

Frequency

: 136.000 MHz

Level

: 10 µV* (–87 dBm)

Modulation

: 1 kHz

Deviation

: ±3.5 kHz

• Receiving

• Operating CH

: CH11

• Connect an SSG to the antenna con-

nector and set as:

Frequency

: 136.000 MHz

Level

: 4.5 µV* (–94 dBm)

Modulation

: 1 kHz

Deviation

: ±3.5 kHz

• Receiving

• Set an SSG as

:

Level

: 0.25 µV* (–119 dBm)

Modulation

: 1 kHz

Deviation

: ±3.5 kHz

• Receiving

• Operating CH

: CH9

• Connect an SSG to the antenna con-

nector and set as:

Frequency

: 155.000 MHz

Level

: 0.18 µV* (–122 dBm)

Modulation

: 1 kHz

Deviation

: ±3.5 kHz

• Receiving

RX
SENSITIVITY
[BPF T1],
[BPF T2]

S-METER
[S-METER]

SQUELCH
LEVEL
[SQL]

Connect a SINAD meter with an
8

Ω load to the multi connector

through the JIG cable (*OPC-
966).

Internal speaker

ADJUSTMENT

ADJUSTMENT CONDITION

MEASUREMENT

VALUE

UNIT

LOCATION

CONVENIENT:

The BPF T1, BPF T2 can be adjusted automatically.
q-1: Set the cursor to “BPF ALL” on the adjustment program and then push [ENTER] key.
q-2: The connected PC tunes BPF T1, BPF T2 to peak levels.

or

w-1: Set the cursor to one of BPF T1, T2 as desired.
w-2: Push [ENTER] key to start tuning.
w-3: Repeat w-1 and w-2 to perform additional BPF tuning.

Push [ENTER] key on the connected computer keyboard to
set “S1 level”.

Push [ENTER] key on the connected computer keyboard to
set “S6 level”.

Advertising