Maintenance

6

Operator’s Manual

MAInTenAnCe

ENGINE:

The engine for this unit is governed to operate at speeds

close to 600 RPM (60Hz) throughout the operating load

range.

WARnInG: dO nOT TAMPeR WITH THe

GOveRnOR MeCHAnISM, CHAnGe

THe SeTTInG exPeRIMenTAlly, OR

PuSH THe THROTTle OPen In An

ATTeMPT TO GeneRATe MORe

eleCTRICAl CuRRenT; equIPMenT

dAMAGe OR PeRSOnAl InjuRy MAy

ReSulT.

GOveRnOR SPeed AdjuSTMenT

SHOuld be MAde Only by A jOHn

deeRe SeRvICInG deAleR.

CHECKING ENGINE OIL:

Check oil level before each operation and ensure that it

is maintained per engine manual.

CHANGING ENGINE OIL:

Change oil after the first 25 hours of operation. Thereafter

it should be changed every 50 hours.

. Make sure the unit is on level ground. Run the engine

to warm the oil.

. Stop the engine.
. Remove the oil drain plug. (See Fig. )

CAuTIOn: OIl beInG dRAIned MAy be HOT.

TO ReduCe THe RISk Of buRn InjuRy,

HAndle WITH CARe. dISPOSe Of uSed

OIl PROPeRly.

4. Drain oil while engine is warm, into a suitable

container.

5. Reinstall the oil drain plug.
6. Remove oil gauge and refill with new oil. (Fig. 2)
. Check the oil level as instructed in the engine

manual.

. Wipe up any spilled oil.

(Fig. )

OIL DRAIN PLUG

UPPER LEVEL

(Fig. )