Bi-level pulse, Error messages gvg100 protocol supported commands, Ort, refer to the section – JVC KM-H3000E User Manual

Page 50

Advertising
background image

44

Bi-level Pulse

• Return Loss:

≥30dB to 6 MHz

• Levels: NTSC: 286mV ± 14mV (40 IRE ±2 IRE)

PAL: 307mV (43 IRE)

• Rise Times (10-90%): NTSC 140ns ±20ns PAL:

200ns ±20ns

• Duration: NTSC: 4.7us ±0.1 us PAL: 4.7us ±0.2us

Error Messages

The following error messages may appear when starting your switcher.

GVG100 Protocol Supported Commands

The following tables list the Supported GVG100 commands and controls.

Table 5 Switcher Error Messages

Error Message

Description

Solution

DDR 0 Not Found
DDR 1 Not Found
DDR 0 & 1 Not Found

There is a problem with the switcher DDR
memory. The switcher may be used but
many features will be limited or disabled

Re-start your switcher. If the problem
persists, contact JVC Technical Support
for assistance.

Upgrade PMC?

Your switcher requires a Panel Module
Controller (PMC) upgrade as part of a
software upgrade. The switcher may be
used without the PMC upgrade but may
respond in an unpredictable manner

Allow the PMC upgrade to proceed.
Contact JVC Technical Support for
assistance if you are unsure about
upgrading your switcher.

Table 6 GVG100 Supported Commands

Name

MLE/Keyer

Length

Byte Code

Data/Notes

Read MLE Program Bus

MLE

2

41

Read MLE Preset Bus

MLE

2

42

Read Keyer Bus

Keyer

2

43/44

Write MLE Program Bus

MLE

3

C1

<xpt>

An invalid xpt request
returns a protocol error

Write MLE Preset Bus

MLE

3

C2

<xpt>

An invalid xpt request
returns a protocol error

Write Keyer Bus

Keyer

3

C3/C4

<xpt>

An invalid xpt request
returns a protocol error

Read Analog

MLE/Keyer

3

45

<control>

Write Analog

MLE/Keyer

5

C5

<control>

<lsb>

<msb>

Read Light On/off

MLE/Keyer

3

46/47

Write Light On/off

MLE/Keyer

3

C6/C7

<lamp>

Read Wipe Pattern

MLE

2

48

Write Wipe Pattern

MLE

3

C8

<wipe>

Valid wipes are 0-9, as
per the Wipe Pattern
button numbers. An
invalid wipe number
returns a protocol error.

Read Transition Mode

MLE

2

4A

Advertising