2. If nothing appears on the screen:

a. Check the household circuit breaker.
b. Contact you dealer or authorized service center.

PUMP DOES

Depress "JETS" sensor.

NOT OPERATE

1. If no sound is detected or if a "buzzing" sound is

BUT LIGHT DOES

detected, turn off power to the spa and

contact your dealer or authorized service center.

2. If motor operates but no water flows to jets:

a. Pump may not be properly primed. See

instructions below.

b. Contact dealer or authorized service center.

Pump Priming Instructions: TURN SPA OFF!
Remove waterfall side filter cartridge and insert end of garden hose into
its fitting. Seal-off pipe opening around hose using a large, clean rag and
turn on maximum water flow through the hose. After about 30 seconds,
turn off water, remove hose and rag, reinstall filter and activate pump #1
on high speed. Another method of priming the spa’s pump(s) is as fol-
lows:
1.

Turn off the power to the spa.

2.

Remove the handle from diverter valve #1 (Sec, 8.3, Page 14)

3.

Loosen the diverter valve cap slightly (counterclockwise), listening for
the air to seep out.

4.

Tighten the cap finger-tight, replace the diverter valve handle, and turn
the spa’s power back on.

Note: This method must be used for the single speed pump(s) in all spas
because pump #2 (and J-380 pump #3) are not connected to the filter.

CAUTION: If freezing conditions exist and pump is not opera-
tional, take measures to protect the system from freeze damage.
See “Winterizing” (Page 34).

POOR JET ACTION

1. Make certain the pump is on high speed.
2. Check position of diverter valve
3. Open air control for selected jet system.
4. Check for adequate water level.
5. Check for dirty filter cartridge.
6. Check for dirty filters on both pump #2

footwell suction covers (Page 14).